Image 29
cleaning the printer

cleaning the printer

Cleaning the Corona Wires

note

Clean the corona wires as needed, or each time toner is added.

The illustration with the procedure shows the developer unit removed. This is for ease of illustration only. The developer unit does not need to be removed to clean the corona wires.

The printer has two corona wires that may affect print quality. One is in the top of the OPC drum unit; the other is directly underneath it, inside the printer. If a print shows a vertical streak through the whole page (light or white), the corona wires may be dirty.

1Power off the printer and

unplug the power cord.

Brush Storage

 

2Raise the top of the printer by

firmly pressing the button on the left side of the front panel.

3Lift the corona wire cover from the OPC drum unit.

caution

Be careful not to break the delicate corona wire. Do not press down too hard.

4Slide the corona cleaning brush, located in the top of the OPC drum unit, along the corona wire in the OPC drum unit.

5Replace the corona wire cover on the OPC drum unit. The corona wire cover is marked with ªLº and ªRº to indicate the left right reference, and will snap into place.

Corona Cleaning Brush

Corona Wire

Cover

Cleaning the Corona WiresCorona Wire

Corona Wire

Operator's Guide

19