cleaning the printer
caution
The OPC drum unit is light sensitive. Install it within five minutes.
If the OPC drum can not be installed within five minutes, place the drum in the original packaging to prevent light damage.
When removing the drum unit, do not touch the surface of the drum unit. Fingerprints and scratches can damage the drum surface and cause poor print quality. Do not rotate the drum unit manually. Forced rotation will cause an incorrect count for the life of the drum unit and may cause poor print quality.
6Remove any paper from the printer.
7Remove the OPC drum unit from the printer by lifting up and out. Set the unit aside.
8Slide the corona cleaning brush along the length of the transfer corona wire to remove any dust or debris.
9Place the OPC drum unit into the printer.
10Replace the corona cleaning brush in its holder on top of the OPC drum unit.
11Reload the paper. Refer to the ªLoading Paperº section.
12Close the top cover of the printer and wait for the printer to warm up.
20 | Operator's Guide |