Promise Technology TX4000 user manual Rebuilding a Mirrored Array

Models: TX4000

1 76
Download 76 pages 52.49 Kb
Page 35
Image 35

Chapter 3: FastBuild Configuration Utility

Rebuilding a Mirrored Array

The Rebuild Array (5) Menu option can be used to recover from an error in a mirrored disk array. You will receive an error message when booting your system from the FastTrak BIOS.

Important

Drives MUST be replaced if they contain any physical errors.

Follow these steps before using the Rebuild Array menu option:

1.On boot up, the FastTrak TX4000 Startup BIOS will display an error message identifying which drive has failed.

2.Press Ctrl-F to enter FastBuild Main Menu.

3.Select submenu Define Array (3).

4.Select the failed array and identify the Channel and ID of the failed drive.

5.Power off and physically remove the failed drive.

6.Replace the drive with an identical model.

7.Reboot the system and enter the FastBuild Main Menu.

8.Select the Rebuild Array (5) option. The following screen will appear.

FastBuild (tm) Utility 1.xx (c) 2002-2005 Promise Technology, Inc.

[ Rebuild Array Menu ]

Array No

RAID Mode

Total Drv

Capacity(MB)

Status

Array 1

Stripe

2

16126

Functional

Array 2

Mirror

2

8063

Critical

Array 3

——

——

——

——

Array 4

——

——

——

——

 

 

[ Keys Available ]

 

[] Up [] Down

[ESC] Exit

[Enter] Select

 

 

9.Highlight the array whose Status is Critical.

10.Press Enter. The following screen will then appear (see next page).

31

Page 35
Image 35
Promise Technology TX4000 user manual Rebuilding a Mirrored Array