FastTrak TX4000 User Manual

About Dual Data Redundancy

One unique (though rarely occurring) feature of RAID 0+1 is dual fault tolerance. In some cases, two drives can fail simultaneously and still maintain the integrity of data. There are six combinations in which two drives can fail. FastTrak TX4000 protects the data array in four of those cases depending on drive type (some drives do not permit the Slave drive to continue to function if the Master drive fails).

Assume the drives are configured as follows:

IDE indicates channels on the FastTrak TX4000 card.

A/B indicates which striped pair the drive belongs to.

1/2 indicates which part of stripe data.

IDE 1

IDE2

IDE3

IDE4

 

 

 

 

Drive A1

Drive B1

Drive A2

Drive B2

 

 

 

 

Note that FastTrak TX4000 card does not use Master/Slave drive settings.

Under RAID 0+1, the array maintains data integrity if any A, B combination survives.

 

Failed

Array

 

Event

Drives

Status

Why?

1

A1/A2

Offline

B1/B2 contain only half of array data

 

 

 

 

2

B1/B2

Offline

A1/A2 contain only half of array data

 

 

 

 

3

A1/B2

Functional

B1/A2 retain array integrity

 

 

 

 

4

B1/A2

Functional

A1/B2 retain array integrity

 

 

 

 

5

A1/B1

Functional

B2/A2 retain array integrity

 

 

 

 

6

B2/A2

Functional

A1/B1 retain array integrity

 

 

 

 

52

Page 56
Image 56
Promise Technology TX4000 user manual About Dual Data Redundancy, Failed Array Event Drives Status Why?