IBM INTERFACES
IBM 4683/84 • 4693/94 PORT 5B INTERFACE SELECTION1
Scan this label to enable the IBM 468x Port 5B interface1.
IBM 4683/84 • 4693/94 PORT 5B SETTINGS
Data Format: Send As Code 39 — converts barcode data (UPC/EAN, add- ons, Code 93, Codabar, MSI/Plessey and Code 128) into Code 39 format before sending the data to the host.
These settings are for IBM 4683/84 • 4693/94 Port 5B interface ONLY.
Limit Command Set — is an option that causes the scanner to ignore 'enable scanner' and 'disable scanner' commands sent from the host.
Transmit Unsolicited Status2 — when enabled, this option causes the scanner to transmit a status message to the host upon receipt of a "Set Normal Response Mode" (SNRM) command, and after scanner transmission of a "Non Sequenced Acknowledge" (NSA) response.
SET ------------------------------------- 
  | 
  | SEND AS CODE 39  | 
  | 
  | DON'T SEND AS CODE 39   | 
FORMAT  | 
  | ENABLE LIMIT COMMAND SET   | 
DATA  | 
  | |
  | DISABLE LIMIT COMMAND SET   | |
  | 
  | |
  | 
  | TRANSMIT UNSOLICITED STATUS -  | 
  | 
  | ON'T TRANSMIT UNSOLICITED STATUS  | 
  | D  | 
END ------------------------------------- 
1Scanners manufactured prior to April 30, 1997 do not have IBM interfaces as a selectable option.
2For this IBM interface, the setting for Unsolicited Status is normally Enabled.
8  | SP400RF Programming Guide  |