SETTING SYMBOLOGY SPECIFIC LABEL IDENTIFIERS (LABEL I.D.)

CONTINUED

4.Scan the label representing the symbology whose label identifier you wish to modify.

In our example, we would scan the 'UPC-A' symbology label.

5.Identify and scan the digits that correspond to the Hex Values.

The hex values from the ASCII chart that correspond to 'A1' from our example are as follows: 41hex = 'A', and 31hex = '1'. Thus, we would scandigit programming labels in this order: 4, 1, 3, 1.

6.Scan the END label.

In our example, you have changed the default label iden- tifier prefix for UPC-A from 'A' to 'A1'.

SET -------------------------------------

DISABLE LABEL I.D. CONTROL ----

TRANSMIT LABEL I.D. AS PREFIX -

TRANSMIT LABEL I.D. AS SUFFIX -