GENERAL
FEATURES
R44-1027 91
WAIT TIME FOR HOST ACKNOWLEDGE
The wait time for the Base Station to receive an acknowledge command
from the host is adjustable in twenty millisecond ticks, with a selectable
range from 000 to 255 (0 to 5.1 seconds). The factory default setting for
this feature is 200ms.
WARNING
Wait time for host acknowledge is especially
critical when WACK mode is enabled, and should
be calculated using the formula below.
Wait Time number of barcode characters x number of bits per byte
baud rate + intercharacter
To set the host acknowledge wait time:
1. Determine the desired wait time in twenty millisecond ticks
(for example: sixty).
2. Scan the SET label.
3. Scan the SET WAIT TIME FOR HOST ACKNOWLEDGE label.
4. Set the wait time by scanning the desired amount (note that
three digits are required). In the case of our example; 60
milliseconds would be selected by scanning 0-0-3 (20ms tick
x 3 = 60ms).
5. Scan the END label.
SET -------------------------------------
SET WAIT TIME FOR HOST ACK ----
0-----------------------------
1-----------------------------
2-----------------------------
WAIT TIME FOR HOST
ACKNOWLEDGE