Quadra-Fire 7100FP-BK-B Framing and Clearances, 7100FP EPA Woodburning Fireplace, Fire Risk

Models: 7100FP-BK-B 7100FP-GD-B 7100FP-NL-B

1 68
Download 68 pages 44.2 Kb
Page 10
Image 10
Framing and Clearances

R

7100FP EPA Woodburning Fireplace

 

 

 

 

 

3

Framing and Clearances

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WARNING

 

Note:

 

 

 

 

Illustrations and photos reflect typical installations and

 

Fire Risk

 

 

are FOR DESIGN PURPOSES ONLY.

 

Provide adequate clearances.

 

 

 

Illustrations/diagrams are not drawn to scale.

 

Around air openings

 

 

 

Actual installation/appearance may vary due to individual

 

To combustibles

 

 

 

design preference.

 

For service access.

 

 

 

Hearth & Home Technologies reserves the right to alter

 

Locate fireplace away from traffic areas.

 

 

 

its products.

A. Selecting Fireplace Location

 

considerable air movement can affect the performance and

Several options are available to you when choosing a loca-

 

cause intermittent smoke spillage from the front of the fire-

tion for your fireplace. This fireplace may be used as a room

 

place when no outside air is used. Outside air must be used

divider, installed along a wall, across a corner or used in an

 

for combustion. The 7100FP comes equipped with an out-

exterior chase. See Figure 10.1.

 

side air inlet to feed combustion air from outside the home,

 

 

 

 

along with an outside air termination cap. Consideration

Locating the fireplace in a basement, near frequently opened

should be given to these factors before deciding on a loca-

doors, central heat outlets or returns, or other locations of

tion. See Sections 2 and 10.

 

Note: A minimum 1/2 in. air clearance must be maintained at the back and 1 in. minimum clearance to the sides of the fireplace assembly.

Chimney sections at any level require a 2 in. minimum air space clearance between the framing and chimney sections.

Note: In addition to these framing dimensions, also reference the following sections:

Clearances (Section 3.B.)

Mantel (Section 8.F.)

Fireplace Dimensions (Section 12.A.)

D

E

 

 

A

Across a corner

 

 

 

C

 

 

 

 

 

 

 

 

 

 

24 in.

F

 

 

 

 

 

(610mm)

 

 

 

 

 

 

As a

room H A divider

48in.

(1219mm)

B

G

A

In an exterior chase or projecting into a garage

Along a wall

I

A

24 in.

(610mm)

B

B

24 in.

(610mm)

Model

 

A

B

C

D

E

F

G

H

I

#7100FP

 

 

 

 

 

 

 

 

 

 

in.

41-7/8

16

89-1/2

63-5/16

22-7/16

44-3/4

14-1/16

55-15/16

50-7/8

(Dimensions for

 

1063

406

2273

1608

570

1137

357

1421

1292

finished walls)

mm

Figure 10.1 Fireplace Locations

Page 10

433-1390D

September 7, 2007

Page 10
Image 10
Quadra-Fire 7100FP-BK-B warranty Framing and Clearances, 7100FP EPA Woodburning Fireplace, A. Selecting Fireplace Location