Quadra-Fire 7100FP-BK-B, 7100FP-NL-B, 7100FP-GD-B 7100FP EPA Woodburning Fireplace, Timer Plate

Models: 7100FP-BK-B 7100FP-GD-B 7100FP-NL-B

1 68
Download 68 pages 44.2 Kb
Page 37
Image 37
7100FP EPA Woodburning Fireplace

R

 

 

7100FP EPA Woodburning Fireplace

 

 

 

 

6. Remove 2 screws from timer mounting plate. Figure 8.

Remove old air chamber cover. Place the cover under

37.1.

the bottom of the firebox. Using a 7/16 wrench attach the

 

 

(2) 1/4-20 bolts as shown in Figure 37.4.

Timer Plate

Air Chamber Cover

Attach with 1/4-20 bolts

Figure 37.1

Figure 37.4

7.Place your hand into the access door in the floor of the fireplace. Let the timer assembly and plate drop down and rotate it up through the access door. You will be looking at the back side of the assembly. Figures 37.2 & 37.3.

9.Insert the new timer assembly into the access door with the back side towards you. Please note the correct pos- tion of the linkage lower arm in Figure 37.3.

10.After re-installing the timer assembly through the fire- box access door, re-attach the timer assembly to the air chamber cover using a Phillips head screw driver. Figure 37.5.

Figure 37.2

Arm must be in this position when re-installing

Figure 37.5

11.Attach the linkage upper arm to the lower linkage arm. Figure 36.6 on page 36.

Rotate assembly up and out through access door

Figure 37.3

September 7, 2007

433-1390D

Page 37

Page 37
Image 37
Quadra-Fire 7100FP-BK-B 7100FP EPA Woodburning Fireplace, Arm must be in this position when re-installing, Timer Plate