7100FP EPA Woodburning Fireplace
D. Secure the Fireplace
•Position the Fireplace
This fireplace may be placed on either a combustible or
CAUTION
Sharp Edges
• Wear protective gloves and safety glasses during installation.
•Level the Fireplace
Level the fireplace
WARNING
Fire Risk!
Pallet Mounting
Brackets
1 in. (25mm) Overlap
•Prevent contact with sagging, loose insulation.
•Do NOT install against vapor barriers or exposed insulation.
WARNING
Fire Risk!
•Metal hearth strips MUST be installed. Sparks or embers may ignite flooring.
•Place the Protective Metal Hearth Strips
Included with your fireplace you will find two metal hearth strips measuring approximately 23 in. x 4 in. (584 mm x 102 mm). These strips are used to provide added protection where the fireplace and the hearth ex- tension meet.
Slide each metal strip 2 in. (51 mm) under the front edge of the fireplace. The individual pieces must overlap each other by 1 in. (25 mm) minimum in the middle of the fire- place to provide continuous coverage of the floor. See Figure 19.1. These metal strips should extend from the front and sides of the fireplace opening by 2 in. (51 mm). Nail or screw metal strips in place.
Note: When elevating the fireplace above the hearth extension the front of the elevated platform must be protected with a protective metal hearth strip (not included) as shown in Figure 19.2.
Metal strips 2 in. (51mm) under edge of Fireplace and Hearth Extension and 2 in. (51mm) on both side of fireplace opening.
Nail or screw metal strips in place.
Figure 19.1 Position the Protective Metal Hearth Strips
Top piece must overlap | |
| bottom piece |
Raised Platform |
|
2 in. | 1 in. (25 mm) min. |
(51 mm) | overlap |
| Floor |
2 in. |
|
(51 mm) | Nail or screw metal strips in place. |
Figure 19.2 Protect the Front of an Elevated Platform