7100FP EPA Woodburning Fireplace
7 Accessories
A. Blower Replacement
Blower Cord Location
The 7100FP Fireplace comes standard equipped with two blowers, installed at the factory with electric access on the right side of fireplace (as you face it).
CAUTION
Shock Risk
Disconnect power by turning off circuit breaker BEFORE servicing.
Blower Replacement Instructions
1.Remove the brick from the bottom of the fireplace and 3 of the back vertical bricks.
2.Remove the 2 screws from the access panel in the fire- box floor. See Figure 31.1.
3.Pry up the access panel using the screwdriver slot and completely remove the panel.
| Screws |
| Screwdriver Slot |
Figure 31.1 | Accessing Blower Motor |
Unplug wire harness before removing fan
Figure 31.2 Blower Motor
3.Connect new blower wires to wire harness.
4.Before installing the blower, make sure the grommets are tightly in place. Insert the right blower and place over the 2 locating pins. Repeat for other blower. Figure 31.3.
Figure 31.3 Installing Blowers
5.
6 Replace the brick that was removed.
7. Reconnect the power.
Removing the Blower
1.Unplug the wire harness.
2.Lift blower from locating pins and remove. Repeat for second blower if necessary. See Figure 31.2.
September 7, 2007 | Page 31 |