Quadra-Fire 7100FP-NL-B warranty 7100FP EPA Woodburning Fireplace, E. Timer Assembly Replacement

Models: 7100FP-BK-B 7100FP-GD-B 7100FP-NL-B

1 68
Download 68 pages 44.2 Kb
Page 36
Image 36
E. Timer Assembly Replacement

R

7100FP EPA Woodburning Fireplace

E. Timer Assembly Replacement

Be careful not toCAUTION

Shock Risk

Disconnect power by turning off circuit breaker BEFORE servicing.

1.Remove both doors, fascia and brick.

2.Remove 2 Phillips head screws and pry open access door in the bottom of the fireplace with a flat head screw- driver. Figure 36.1.

4.You will need to disconnect air chamber cover from timer assembly before installing in the fireplace. Set screws aside for later use. Figure 36.4.

Remove 2 screws

Remove 2 screws and pry open access door.

Figure 36.4

Figure 36.1 Open Access Door

3.Remove 2 screws and take off access cover. Figure 36.2.

Figure 36.2 Access Cover

NOTE: The timer assembly included in this kit comes with the air chamber cover attached. Figure 36.3.

Air Chamber Cover is attached to Timer Assembly

Figure 36.3 Timer Assembly with Air Chamber Cover (Linkage arm is not included in the kit)

Figure 36.5

5.Remove 2 screws from timer linkage upper arm. Be careful NOT TO DROP arm in bottom of fireplace. Figure 36.6.

Be careful not to

Move arm left drop Linkage Arm down into fireplace

Figure 36.6

Page 36

433-1390D

September 7, 2007

Page 36
Image 36
Quadra-Fire 7100FP-NL-B 7100FP EPA Woodburning Fireplace, E. Timer Assembly Replacement, Be careful not to, Shock Risk