R
7100FP EPA Woodburning Fireplace
E. Timer Assembly Replacement
CAUTION
Shock Risk
Disconnect power by turning off circuit breaker BEFORE servicing.
1.Remove both doors, fascia and brick.
2.Remove 2 Phillips head screws and pry open access door in the bottom of the fireplace with a flat head screw- driver. Figure 36.1.
4.You will need to disconnect air chamber cover from timer assembly before installing in the fireplace. Set screws aside for later use. Figure 36.4.
Remove 2 screws
Remove 2 screws and pry open access door.
Figure 36.4
Figure 36.1 Open Access Door
3.Remove 2 screws and take off access cover. Figure 36.2.
Figure 36.2 Access Cover
NOTE: The timer assembly included in this kit comes with the air chamber cover attached. Figure 36.3.
Air Chamber Cover is attached to Timer Assembly
Figure 36.3 Timer Assembly with Air Chamber Cover (Linkage arm is not included in the kit)
Figure 36.5
5.Remove 2 screws from timer linkage upper arm. Be careful NOT TO DROP arm in bottom of fireplace. Figure 36.6.
Be careful not to
Move arm left drop Linkage Arm down into fireplace
Figure 36.6
Page 36 | September 7, 2007 |