D. Assemble the Chimney Sections
Attach either a straight chimney section or an offset to the top of the fireplace (depending on your installation require- ment). Chimney sections are locked together by pushing downward until the top section meets the stop bead on the lower section.
The inner flue is placed to the inside of the flue section below it. The outer casing is placed outside the outer casing of the chimney section below it. See Figure 23.1.
If you are using a different approved venting system, follow the instructions that were supplied with that system.
E.Assembling Chimney Sections for the SL- 300 Series
NOTE: Chimney Air Kit, Part CAK4A is REQUIRED when using the
If using the Dura-Plus System (must be 8 in. (203
mm)in diameter), the starter ring that came with the fireplace must be removed and replaced with the
Installing CAK4A and Flex Pipe
Figure 23.1 Assembling Chimney Sections |
Note: Inner flue and outer liner sections cannot be disassembled once locked together. Plan ahead to ensure the proper installation height is achieved with the selected chimney components.
WARNING
Fire Risk
Do NOT install substitute or damaged chimney components.
•MUST use chimney system described in this manual.
•NO OTHER chimney components may be used.
Substitute or damaged chimney components may impair safe operation.
NOTE: FOLLOW DETAILED INSTRUCTIONS THAT COME WITH THE CAK4A.
1.Install the chimney pipe first.
2.Hand bend the tabs in position before placing on the fireplace.
3.Place the box on top of the fireplace around the chimney pipe, push both pieces together and secure with screws provided.
4.Use the
5.Secure the CAK4A in place.
6.Seal around the kit at the flue and at the top of the can with caulk.
Attach
Flue First
Secure with Screws
Provided
CAK4A
Push Together
Secure to Top
Figure 23.2 Installing the CAK4A
NOTES:
1.The outside air termination cap must be a minimum of 6 ft (1829 mm) above the ground and kept free of debris and must be at least 3 ft (914 mm) below the chimney top, if installed in the chase zone.
2.Seal around the cap and flex with caulk to stop air from getting in to the chase (See Figure 24.1 on page 24).