Quadra-Fire 7100FP-BK-B 7100FP EPA Woodburning Fireplace, D. Electrical Access and Wiring Diagram

Models: 7100FP-BK-B 7100FP-GD-B 7100FP-NL-B

1 68
Download 68 pages 44.2 Kb
Page 13
Image 13
Suggestions:

R

7100FP EPA Woodburning Fireplace

Suggestions:

1.Insulate chase.

2.Finish chase walls with dry wall 5/8 in. (16mm) Type X face tape.

3.All dimensions are to finished walls and ceilings.

Figure 13.1 Sheetrocked Chase

D. Electrical Access and Wiring DiagramWARNING

Fire Risk

Comply with all minimum clearances speci- fied.

A minimum 1/2 in. (13mm) air clearance must be maintained at the back and 1 in. (25mm) to the sides of the fireplace assembly.

Chimney sections at any level require a 2 in. (51mm) minimum air space clearance between the framing and chimney section.

Manual backgroundWARNING

Fire Risk

Do not apply combustible finishing materials over any part of the front of this fireplace.

The metal fireplace face may only be covered with noncombustible materials such as ceramic tile, brick, or stone.

Do not cover or block any cooling air slots.

The decorative fascia must be removable for future serviceability of the Automatic Combustion Control.

Manual backgroundWARNING

Fire Risk

Maintain clearances.

Use only non-combustible material below standoffs, material such as cement board is acceptable.

Framing or finishing material used on the front of, or in front of, the appliance closer than the minimums listed, must be constructed entirely of noncombustible materials (i.e., steel studs, concrete board, etc.).

D. Electrical Access and Wiring Diagram

NOTE: The manual override switch, rheostat speed control and cover plate are supplied. You will need to supply: 14-3 wire with ground; 14-2 wire with ground; standard wall mount junction box; wire nuts.

1.Remove junction box cover plate on the bottom right side of the fireplace.

2.Thread the 14-3 with ground wire through the opening with the strain relief on the cover plate.

3.Match colors to wire harness, (red to red, white to white, etc) and secure with wire nuts.

NOTE: Wiring for blowers must be done before framed enclosure is completed. If using a Heat Zone kit, it also must be installed before enclosure is complete.

 

14-3 w/ground

Match colors to wire

WHITE

harness (red to red,

 

white to white, etc) and

 

secure with a wire nut

 

Power to the Fireplace

 

Snap Disc

RED

bypass switch

 

BLACK

Figure 13.2 Fan Wiring Diagram

Standard wall mount with

Junction Box

Manual background14-2 w/ground

WIRE NUT

WHITE

GREEN

BLACK

(110V)

 

Incoming Power

September 7, 2007

433-1390D

Page 13

Page 13
Image 13
Quadra-Fire 7100FP-BK-B 7100FP EPA Woodburning Fireplace, D. Electrical Access and Wiring Diagram, Suggestions, Fire Risk