7100FP EPA Woodburning Fireplace
Suggestions:
1.Insulate chase.
2.Finish chase walls with dry wall 5/8 in. (16mm) Type X face tape.
3.All dimensions are to finished walls and ceilings.
Figure 13.1 Sheetrocked Chase
WARNING
Fire Risk
Comply with all minimum clearances speci- fied.
•A minimum 1/2 in. (13mm) air clearance must be maintained at the back and 1 in. (25mm) to the sides of the fireplace assembly.
•Chimney sections at any level require a 2 in. (51mm) minimum air space clearance between the framing and chimney section.
WARNING
Fire Risk
Do not apply combustible finishing materials over any part of the front of this fireplace.
•The metal fireplace face may only be covered with noncombustible materials such as ceramic tile, brick, or stone.
•Do not cover or block any cooling air slots.
The decorative fascia must be removable for future serviceability of the Automatic Combustion Control.
WARNING
Fire Risk
•Maintain clearances.
•Use only
•Framing or finishing material used on the front of, or in front of, the appliance closer than the minimums listed, must be constructed entirely of noncombustible materials (i.e., steel studs, concrete board, etc.).
D. Electrical Access and Wiring Diagram
NOTE: The manual override switch, rheostat speed control and cover plate are supplied. You will need to supply:
1.Remove junction box cover plate on the bottom right side of the fireplace.
2.Thread the
3.Match colors to wire harness, (red to red, white to white, etc) and secure with wire nuts.
NOTE: Wiring for blowers must be done before framed enclosure is completed. If using a Heat Zone kit, it also must be installed before enclosure is complete.
| |
Match colors to wire | WHITE |
harness (red to red, |
|
white to white, etc) and |
|
secure with a wire nut |
|
Power to the Fireplace |
|
Snap Disc | RED |
bypass switch | |
| BLACK |
Figure 13.2 Fan Wiring Diagram
Standard wall mount with
Junction Box
WIRE NUT
WHITE
GREEN
BLACK | (110V) |
| Incoming Power |
September 7, 2007 | Page 13 |