Size
•Pellets are either 1/4 inch or 5/16 inch
•Length should be no more that
•Pellet lengths can vary from lot to lot from the same manufacturer
•Due to length variations, the flame height (feed rate) may need adjusting occasionally. See page 27 for instructions..
Performance
•Higher ash content requires the ash drawer to be emptied more frequently
•Hardwoods require more air to burn properly
•Set wall control to “Utility Pellet” if the fi repot and ash pan are fi lling quickly. This will cause the
•Premium wood pellets produce the highest heat output.
•Burning pellets longer than
D. General Operating Information
Read and understand the Thermostat Wall Control manual for detailed operating instructions. The wall control is an intregal part of how to operate this appliance.
1. Thermostat Wall Control - Automatic Setting
The appliance is like most modern furnaces; when the thermostat wall control calls for heat, your appliance will automatically light and deliver heat.
When the room is up to temperature and the wall control is satisfi ed the appliance will shut down.
In the automatic setting the heat output level is controlled by the wall control. Select “Automatic” on the AUTO/MANUAL screen. Figure 26.1.
We recommend that you buy fuel in
CAUTION! Tested and approved for wood pellets, shelled
field corn, wheat and black oil sunfl ower seeds. Burning of any other type of fuel voids your warranty.
Changing to Different Fuel Type
•Empty the hopper of the previous fuel
•Thoroughly vacuum hopper before fi lling with the new fuel
•Select the appropriate setting on the FUEL SELECTION screen on the thermostat wall control
The burn rate, BTU content and heat output will all vary depending on the fuel selected.
Storage
•Wood pellets should be left in their original sealed bag until using to prevent moisture absorption.
•Shelled corn, wheat or sunfl ower seeds should be stored in a tight container to prevent it from absorbing moisture from damp or wet fl oors.
•This will also prevent rodents from becoming a problem.
•Do not store any pellet fuel within the clearance requirements or in an area that would hinder routine cleaning and maintenance.
CAUTION
Tested and approved for wood pellets, shelled fi eld corn, wheat and black oil sunfl ower seeds. Burning of any other type of fuel voids your warranty.
Automatic
Manual
Off
Figure 26.1
2. Thermostat Wall Control - Manual Setting
When you select “Manual” on the AUTO/MANUAL screen the appliance will still automatically turn on and off according to the temperature setting.
However, you will be able to manually control the heat output levels. Adjust the heat output levels by using the HEAT OUTPUT LEVEL screen. Figure 26.2.
Medium
Figure 26.2
3. Auto-Clean Firepot System
Your appliance is equipped with an automatic fi repot cleaning system that will change the frequency of cleaning based on the fuel being burned.
The
NOTE: User is responsible for removing the ash from the ash drawer.