Mt. Vernon Pellet Insert (AE)

R

1Listing and Code Approvals

A. Appliance Certifi cation

E. BTU & Effi ciency Specifi cations

MODEL:

Mt. Vernon Pellet Insert AE

LABORATORY:

OMNI Test Laboratories, Inc

 

 

REPORT NO.

061-S-69-6

 

 

TYPE:

Solid Fuel Room Heater/Pellet Type

 

Insert

 

 

STANDARD:

ASTM E1509-04, ULC S628-93 and

 

ULC/ORD-C1482-M1990 Room Heater

 

Pellet Fuel Burning Type and (UM) 84-

 

HUD, Mobile Home Approved

 

 

FCC

Complies with Part 15 of FCC Rules.

 

Operation is subject to the following

 

two conditions: (1) this device may not

 

cause harmful interference, and (2) this

 

device must accept any interference

 

received, including interference that

 

may cause undesired operation.

 

 

B. Mobile Home Approved

This appliance is approved for mobile home installations when not installed in a sleeping room and when an outside combustion air inlet is used.

The structural integrity of the mobile home fl oor, ceiling, and walls must be maintained.

The appliance must be properly grounded to the frame of the mobile home and use only Listed pellet vent Class “L” or “PL” connector pipe.

A Quadra-Fire Outside Air Kit must be installed in a mobile home installation. You must order the Outside Air Kit sepa- rately.

Note: The appliance is also approved for installation into a shop.

C. Glass Specifi cations

This appliance is equipped with 5mm ceramic glass. Replace glass only with 5mm ceramic glass. Please contact your dealer for replacement glass.

NOTE: This installation must conform with local codes. In the absence of local codes you must comply with the ASTM

E1509-04, ULC S628-93, ULC/ORD-C-1482-M1990 and

(UM) 84-HUD.

Emissions Rating:

EPA Compliant

 

 

*BTU Output:

14,620 - 60,200 / hr

 

 

Effi ciency:

81.4% - 83.6%

 

 

Heating Capacity:

1,775 - 3,089 square feet depend-

 

ing on climate zone

 

 

Hopper Capacity:

56 lbs +/- 5 lbs

 

 

Fuel:

Pellets, Shelled Field Corn, Wheat

 

and Black Sunfl ower Seeds

 

 

Shipping Weight:

425 lbs.

 

 

*BTU output will vary, depending on the brand of fuel you use in your appliance. Consult your Quadra-Fire dealer for best results.

WARNING! Risk of Fire! Hearth & Home Technologies dis- claims any responsibility for, and the warranty and agency listing will be voided by the above actions.

DO NOT:

Install or operate damaged appliance

Modify appliance

Install other than as instructed by Hearth & Home Technologies

Operate the appliance without fully assembling all components

Overfi re

Install any component not approved by Hearth & Home Technologies

Install parts or components not Listed or approved. Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage.

For assistance or additional information, consult a qualifi ed installer, service agency or your dealer.

NOTICE: Hearth & Home Technologies, manufacturer of this appliance, reserves the right to alter its prod- ucts, their specifi cations and/or price without notice.

Quadra-Fire is a registered trademark of Hearth & Home Technologies.

D. Electrical Rating

115 VAC, 60 Hz, Start 5 Amps, Run 1.25 Amps