Mt. Vernon Pellet Insert (AE)

R

G. Convection Blower Replacement (Cont’d)

Convection Blower Replacement

1.After the sides are removed, reach behind the blower and release the latch by pushing the top of the latch towards the blower. Figure 42.1.

2.Rock the top of the blower slightly and lift up and out. The blower will pass around the control board and out the side of the appliance.

3.Disconnect the wire harness from the bottom of the blower by depressing the tabs on the sides of the con- nector and then pulling to remove. Figure 42.2.

4.Re-connect wire harness to the new replacement blower. Install the blower by placing the bottom fl ange into the opening fi rst then rotate blower up into posi- tion.

5.When the blower is properly positioned the latch will engage the notch to hold the blower in place. Figure 42.3.

Latch Engaged

Figure 42.3

NOTCH

LATCH

Figure 42.1

CONVECTION

BLOWER

DISCONNECT WIRE HARNESS

FROM BOTTOM OF BLOWER

Figure 42.2

Page 42

7036-135G

November 22, 2011

Page 42
Image 42
Quadra-Fire MTVERNINSAE-MBK, MTVERNINSAE-CSB, MTVERNINSAE-PMH, MTVERNINSAE-CWL Convection Blower Replacement Cont’d