Mt. Vernon Pellet Insert (AE)

R

17.Power Supply

The power supply is located at the bottom left side of the appliance. It converts 120 volt AC current to 15 volt DC current to power the appliance.

18.Overheat Sensor (Snap Disc)

The overheat sensor is mounted on the back of the drop tube in the center of the appliance and has a reset button. To access it remove the right side panel. If the fi re tries to burn back into the feed system or push exhaust up the feed tube, this sensor will shut the appliance down, however the wall control will continue to display messages. This sensor must be manually reset. Disconnect power before resetting.

19.Thermocouple - Firepot

The thermocouple is located on top of the fi repot inside the thermocouple cover (ceramic protection tube). The thermocouple sends a millivolt signal to the control board telling the control board there is a fi re in the fi repot.

20.Thermocouple on Drop Tube

21.Vacuum Switch

The vacuum switch is located on the right side of the appliance under the feed motor behind the right side panel and connects to the drop tube with a hose. This switch turns the feed system on when vacuum is present in the fi rebox. The vacuum switch is a safety device designed to shut off the feed motor if the exhaust or the heat exchanger system is dirty or plugged or if the fi rebox door is open.

22.Wall Control Thermostat

The appliance is designed to run on a custom designed 3.3 volt DC thermostat wall control. It will not operate on any other wall control. Refer to the instructions supplied with the appliance located in the component packl.

23.Wiring Connections for Power Supply

See Figure 44.1.

24.Wiring Connection for Control Board See Figure 44.2.

The thermocouple is located on the bottom of the drop tube on the right side and is attached with a wing nut. It turns the convection blower on and off, varies the speed of the convection blower and will shut down the appliance if internal heat exceeds set temperature.

Heat sinks are taped to cover for shipping. Slowly lift cover and cut the tape holding them in place and then you can remove the cover.

Fuse

15A 250V

Input Line

Input Line Voltage

15V DC out to

Voltage

AC out to Control

Control Board

 

Board

 

Power Supply shown with cover removed

13

FUSE 15A 120V,

UNDER THE COVER

14

12

11

N/a

10

9

8

7

6

5

4 3 2

1

 

 

 

FUSE 15A 120V,

15

16

17

UNDER THE COVER

 

Figure 44.1 - Power Supply

Figure 44.2 - Control Board

 

#Description

1Combustion Blower

2 Auto-Clean System

3 Feed/Auger Motors

4 Hopper/Door Switches

5Auger/Auto Clean/Vacuum Switches

6Low Fuel

#Description

7Thermostat Wall Control

8Combustion Blower (feedback)

9 Firepot Thermocouple

10 Drop Tube Thermocouple n/a Not Used

11 Convection Blower (feedback) n/a Not Used

#Description

11Convection Blower (feedback)

12Igniter

13AC Power In for Igniter

14Convection Blower Power

15Overheat Sensor (Snap Disc)

16DC Power In from Power Supply

1712 Volt Battery Back-up

Page 44

7036-135G

November 22, 2011

Page 44
Image 44
Quadra-Fire MTVERNINSAE-CSB Power Supply, Overheat Sensor Snap Disc, Thermocouple Firepot, Wall Control Thermostat