Items for Specifying Scan Settings

A Press [Scan Settings].

B Press [Scan Size].

C Press [Custom Size].

D Specify Original Size (X1 and Y1) using the number keys, and then press {q}.

For example, set X1 to 300 mm and Y1 to 200 mm.

6

E Specify Start Position (X2 and Y2) using the number keys, and then press {q}.

For example, set X2 to 30 mm and Y2 to 20 mm.

F Specify Scan Area (X3 and Y3) using the number keys, and then press {q}.

For example, set X3 and Y3 to 80 mm.

G Press [OK].

H Check Scan Area (X3 and Y3) are displayed above [Custom Size], and then press [OK].

111