Various Scan Settings
Scan Settings When Using Twain Scanner
This section explains how to specify original orientation and scan setting for a bundle of mixed size originals when using the TWAIN scanner.
Setting Original Orientation on the TWAIN Scanner
To correctly display the top/bottom orientation of the scanned original on a client computer, the placement of the original and the settings made in the Scanner Control dialog box must match.
A Open the Scanner Control dialog box.
For details about how to open the Scanner Control dialog box, see "Basic Network TWAIN Scanner Operation".
| B In the [Original Scan Method:] list, select the place where the original is placed. | ||||||||
| C In the [Orig.Orientn.:] list, select [ |
| ] or [ | ]. |
|
| |||
| D In | the [Orientation:] | list, select | [ | / | ], [ | / | ], | |
6 | |||||||||
[ | / | ], or [ | / | ]. |
|
|
|
E If an original is placed in the ADF, from the drop down menu of [Scan Settings ], select [1 Sided], [2 Sided(Top to Top)], or [2 Sided(Top to Bottom)].
Reference
p.103 “Basic Network TWAIN Scanner Operation”
Placing Originals
The following table shows the relationship between the original orientation and the Scanner Properties dialog box settings:
❖Exposure Glass
Original Orientation | TWAIN Scanner Control Dialog Box Key |
top edge touches top left of exposure glass
This orientation is the TWAIN driver's standard setting. Place originals in this orientation normally.
top edge touches rear of exposure glass
140