SECTION 16: REMOVAL AND REPLACEMENT PARTS

16.3 Ignition Electrode and Flame Probe.

Burners

Fan/Limit Thermostat

 

Secondary

 

Limit

 

Thermostat

Flame

Flame

Probe

Probe

Remove all

burner compartment

 

screws to remove

 

the burner

Remove

compartment and

Screw

access the

 

“Front View”.

 

Burner Compartment

Front Views

Ignition

Electrode

Ignition

Electrode

(3 mm)

.120" spark gap

Burners

To replace the Ignition Electrode or Flame probe, remove the electrical lead and screw. Pull out from mounting. Refit in reverse ensuring that the gap to burner is as shown in the Front View of the Burner Compartment.

Description

Part Number

Spark Electrode

90427411

Automatic Ignition Flame Probe

90439300

Burners (all models)

92000000

37

Page 43
Image 43