16.2 Burner Compartment

DUALAIR® HEATING AND COOLING UNITS INSTALLATION OPERATION AND SERVICE MANUAL

16.2 Burner Compartment

The burner compartment is a sealed compartment. Following any work, re-seal the compartment with the gas pipe rubber seal fully in place and all screws fitted and tight.

Burner

compartment

cover

Flame probe

Viewing port

for flame probe

Remove flexible

air duct from spigot

Ignition electrode

Viewing port

for ignition electrode

Remove

access plate Rubber Seal

Remove screws and pull off burner cover

16.2.1 Burner Injectors

Ensure gas tight fitting of injectors.

 

Ensure correct alignment with burners.

 

Ensure all pipe joints are gas tight.

Manifold

Remove manifold

screws and pull

out manifold

16.2.1 Burner Injectors Manifold

Unscrew

Injectors

Burner venturi

Marking

Ensure gas tight fitting of injectors.Ensure correct alignment with burners.Ensure all pipe joints are gas tight. Burners Manual backgroundInjectors

Manual background Burner Manual backgroundManual backgroundscrews

 

MODEL

75

90

 

100

115

 

Injector Quantity

12

14

 

15

17

 

 

 

 

Natural

Gas (G20) and (G25)

 

 

 

Injector Size

mm dia

2.71

2.71

 

2.71

2.71

 

 

 

 

 

 

 

 

 

 

in dia

0.1067

0.1067

 

0.1067

0.1067

 

 

 

 

 

Marking

 

36

36

 

36

36

 

RG P/N

 

91930036

91930036

 

91930036

91930036

 

 

 

 

LPG Gas Propane

(G31) and LPG Gas

Butane (G30)

 

 

Injector Size

mm dia

1.51

1.51

 

1.51

1.51

 

 

in dia

0.0594

0.0594

 

0.0594

0.0594

 

 

 

 

 

Marking

 

53

53

 

53

53

 

RG P/N

 

91930053

91930053

 

91930053

91930053

36