150
Chapter 9 Parameter Guide MASTER

CONTROL ASSIGN

Adjust these settings if you would like to use a pedal connected to
the VG-99, or an external MIDI device (control source) to control
parameters as you play.
You can set two parameters as targets to each control source.

* Turn on the COSM guitar, COSM amp, and effect that contains the
parameter you wish to control.

MASTER

GK VOL (GK Volume)

Parameter/
Range Explanation

SW (Switch)

OFF, ON This setting switches GK VOL on and off.

TARGET PARAMETER

This selects the parameter to be changed.
Refer to

“TARGET PARAMETER”

(p. 157).

MIN (Minimum)

This sets the minimum value for the range in which the parameter
can change.
The value differs depending on the parameter assigned for TARGET
PARAMETER.

MAX (Maximum)

This sets the maximum value for the range in which the parameter
can change.
The value differs depending on the parameter assigned for TARGET
PARAMETER.

RANGE LOW, RANGE HIGH

Low: 0–126
High: 1–127
You can set the controllable range for target
parameters within the GK Volume’s opera-
tional range. Target parameters are con-
trolled within the range set with RANGE
LOW and RANGE HIGH. You should nor-
mally set RANGE LOW to 0 and RANGE
HIGH to 127.

GK S1, S2

(DOWN/S1, UP/S2 Switch)

Parameter/
Range Explanation

SW (Switch)

OFF, ON This setting determines whether control
using DOWN/S1 and UP/S2 is switched on
or off.

TARGET PARAMETER

This selects the parameter to be changed.
Refer to

“TARGET PARAMETER”

(p. 157).

MIN (Minimum)

This sets the minimum value for the range in which the parameter
can change.
The value differs depending on the parameter assigned for TARGET
PARAMETER.

MAX (Maximum)

This sets the maximum value for the range in which the parameter
can change.
The value differs depending on the parameter assigned for TARGET
PARAMETER.

MODE

Specify how the value will change in response to an operation.

* When the DOWN/S1, UP/S2 POSI of the GK SETTING is set to
REVRSE position, the function of DOWN/S1, UP/S2 will be
reversed.
* When KEY/BPM/AMPCTL:BPM TAP, FX–DELAY(HOLD)–
REC, or FX–DELAY(HOLD)–STOP is set for the TARGET
PARAMETER, control is available regardless of whether DOWN/S1
or UP/S2 is pressed. In this case, the MODE setting is disabled.

S1: DEC
S2: INC
S1 will decrease the value, and S2 will in-
crease it.
S1: INC
S2: DEC
S2 will decrease the value, and S1 will in-
crease it.
S1: MIN
S2: MAX
The value will be at MIN when S1 is
pressed.
The value will be at MAX when S2 is
pressed.
S1: MAX
S2: MIN
The value will be at MAX when S1 is
pressed.
The value will be at MIN when S2 is
pressed.
VG-99_e.book 150 ページ 2007年7月5日 木曜日 午前9時22分