INSTALLER
INSTALLATION MENU
Basic Setup (cont’d.)
ii.TEMPLATE TYP – (TType)
b.Selected: Unassigned (Unasg)
c.All Other Selections:
4.DEVICE CODE – (DevCd)
5.TEST IR? – (TstIR)
6.SUCCESS? – (OK?)
7.USE NUM IR? – (NumIR)
8.HIGHEST NUM – (High#)
9.AUTO PLAY? – (AtoPl)
10.SAVE CHANGES? – (Save?)
Select the template type to define what type of source compo- nent is being used. (This will tell the CAV 6.6 how to configure the key commands and text for the source component if it is a learned source.) Procedure advances to USE NUM IR? (step 7).
The template for the selected source is cleared. (All key assignments and other source settings will be erased.) Procedure advances to SAVE CHANGES (step 10)
Procedure advances to DEVICE CODE (step 4)
Enter source component code number listed in this manual’s Reference section.
If “Yes” is selected, the CAV 6.6 sends a power command to the source component. If “No” is selected, the procedure advances to USE NUM IR? (step 7)
If the power to the source component was turned off, select “Yes” otherwise select “No.” By selecting “No” the Procedure returns to DEVICE CODE (step 4) to allow selection of another code number from the provided list.
Indicates the source component has numeric scrolling, such as
Enter the highest possible number; for example, a
“Yes” tells the CAV 6.6 to issue a PLAY command whenever the source is selected for listening. This option is skipped if the source type (COMMAND TYPE) chosen does not have a PLAY command associated with it.
Select “yes” to save changes. Procedure returns to SOURCE NUM to allow configuration of another source.
KEY CONFIG (KeyCf)
Key Configuration defines
1. ZONE NUM – | Select the zone the key will be configured for. Changes are made |
(Zone#) | for that zone only; default setting is “All Zones.” |
56