2-2-2. Outdoor Unit

Outdoor Unit CH1872

Control PCB

Part No.

Controls

Control Circuit Fuse

Compressor

CB-CH1872

Microprocessor

250V 25A

 

Type

 

 

DC Twin Rotary (Hermetic)

 

Compressor Model / Nominal Output

 

 

C-6RVN93H0M / 1,050W

 

Compressor Oil ... Amount

Pints (cc)

FV50S ... 0.74 (350)

 

Coil Resistance (Ambient Temp. 68 °F (20 °C)) Ohm

R - S : 0.482

 

 

 

 

 

S - T : 0.482

 

 

 

 

 

T - R : 0.482

 

Safety Device

 

 

Yes

 

 

CT (Peak current cut-off control)

 

 

Compressor Discharge Temp. Control

Yes

 

 

Operation cut-off control in abnormal ambient Temp.

Yes

 

 

Overload Relay

 

Model

CS-7L115

 

 

 

Operation Temp.

Open : 239 °F (115 °C), Close : 203 °F (95 °C)

 

Run Capacitor

 

Micro F

-

 

 

 

 

VAC

-

 

Crankcase Heater

 

 

-

Fan

Type

 

Q'ty ... Dia.

inch (mm)

Propeller

1 ... D16-17/32 (D420)

Fan Motor

 

 

 

Type

 

DC Motor

 

Model ... Q'ty

 

DAJ12-55J71A-CU ... 1

 

No. of Poles

 

8

 

Rough Measure RPM (Cool / Heat)

 

820 / 850

 

Nominal Output

W

50

 

Coil Resistance

Ohm

RED - WHT : 77.5

 

(Ambient Temp. 68 °F (20 °C))

 

WHT - BLU : 77.5

 

 

 

 

BLU - RED : 77.5

 

Safety Device

 

 

 

 

Type

 

Internal Controller

 

 

Over- Current Protection

 

Yes

 

Run Capacitor

Micro F

-

 

 

 

VAC

-

 

 

 

 

 

Heat Exchanger Coil

 

 

 

Coil

 

Aluminum Plate Fin / Copper Tube

 

Rows

 

2

 

Fins per inch

 

21.2

 

Face Area

ft2 (m2)

5.49 (0.510)

External Finish

Acrylic baked-on enamel finish