2-2-2. Outdoor Unit
Outdoor Unit CH1872
Control PCB
Part No.
Controls
Control Circuit Fuse
Compressor
Microprocessor
250V 25A
| Type |
|
| DC Twin Rotary (Hermetic) | |
| Compressor Model / Nominal Output |
|
| ||
| Compressor Oil ... Amount | Pints (cc) | FV50S ... 0.74 (350) | ||
| Coil Resistance (Ambient Temp. 68 °F (20 °C)) Ohm | R - S : 0.482 | |||
|
|
|
|
| S - T : 0.482 |
|
|
|
|
| T - R : 0.482 |
| Safety Device |
|
| Yes | |
|
| CT (Peak current | |||
|
| Compressor Discharge Temp. Control | Yes | ||
|
| Operation | Yes | ||
|
| Overload Relay |
| Model | |
|
|
| Operation Temp. | Open : 239 °F (115 °C), Close : 203 °F (95 °C) | |
| Run Capacitor |
| Micro F | - | |
|
|
|
| VAC | - |
| Crankcase Heater |
|
| - |
Fan
Type |
|
Q'ty ... Dia. | inch (mm) |
Propeller
1 ...
Fan Motor |
|
| ||
| Type |
| DC Motor | |
| Model ... Q'ty |
| ||
| No. of Poles |
| 8 | |
| Rough Measure RPM (Cool / Heat) |
| 820 / 850 | |
| Nominal Output | W | 50 | |
| Coil Resistance | Ohm | RED - WHT : 77.5 | |
| (Ambient Temp. 68 °F (20 °C)) |
| WHT - BLU : 77.5 | |
|
|
|
| BLU - RED : 77.5 |
| Safety Device |
|
| |
|
| Type |
| Internal Controller |
|
| Over- Current Protection |
| Yes |
| Run Capacitor | Micro F | - | |
|
|
| VAC | - |
|
|
|
|
|
Heat Exchanger Coil |
|
| ||
| Coil |
| Aluminum Plate Fin / Copper Tube | |
| Rows |
| 2 | |
| Fins per inch |
| 21.2 | |
| Face Area | ft2 (m2) | 5.49 (0.510) |
External Finish
Acrylic
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
12