2. SPECIFICATIONS
2-1. Unit Specifications
Indoor Unit | KHS1872 |
|
|
|
|
|
|
|
| ||||
Outdoor Unit | CH1872 |
|
|
|
|
|
|
|
|
| < 230V > | ||
|
|
|
|
|
|
|
|
|
|
|
|
| |
Voltage Rating |
|
|
|
|
|
| 230V | ||||||
Performance |
|
|
|
|
|
|
|
|
| Cooling |
|
| Heating |
| Total Capacity |
|
|
|
| BTU/h | 17,500 | ( 4,000 to 17,500 ) |
| 20,400 | ( 4,400 to 20,400 ) | ||
|
|
|
|
|
|
| kW | 5.15 | ( 1.2 to 5.15 ) |
| 6.0 | ( 1.3 to 6.0 ) | |
| Sensible Capacity |
|
|
|
| BTU/h |
| 13,100 |
|
| - | ||
| Latent Capacity |
|
|
|
| BTU/h |
| 4,400 |
|
| - | ||
| Air Circulation (High) |
|
| ft3/min (m3/h) |
| 524 (890) |
|
| 541 (920) | ||||
|
| Moisture Removal (High) |
|
| Pints/h |
| 4.89 |
|
| - | |||
|
| Available Voltage Range |
|
| V |
| 187 to 253 |
| |||||
Rating | Running Amperes |
|
|
|
| A | 7.0 | ( 1.2 to 7.0 ) |
| 7.4 | ( 1.3 to 7.4 ) | ||
Power Input |
|
|
|
|
| W | 1,500 | ( 250 to 1,500 ) |
| 1,575 | ( 270 to 1,575 ) | ||
Power Factor |
|
|
|
| % |
| 93 |
|
| 93 | |||
EER |
|
|
|
|
| BTU/h/W |
| 11.7 |
|
| - | ||
Electrical |
|
|
|
|
|
|
|
| |||||
COP |
|
|
|
|
| W/W |
| - |
|
| 3.81 | ||
SEER |
|
|
|
|
| BTU/Wh |
| 20 |
|
| - | ||
HSPF |
|
|
|
|
| BTU/Wh |
| - |
|
| 10 | ||
|
| Compressor Locked Rotor Amperes |
|
| A |
| 17.5 |
| |||||
|
| Fuse or Circuit Breaker Capacity |
|
| A |
| 20 |
|
| ||||
|
| Controls / Temperature Control |
|
|
|
| Microprocessor / I.C. Thermister | ||||||
|
| Control Unit |
|
|
|
|
|
|
| Wireless Remote Control Unit | |||
|
| Timer |
|
|
|
|
|
|
| ||||
|
| Fan Speeds |
|
| Indoor / Outdoor |
| Auto and 3 steps / Auto (Hi, Me, Lo) | ||||||
|
| Airflow Direction (Indoor) |
|
| Horizontal |
| Manual |
| |||||
|
|
|
|
|
|
|
| Vertical |
| Auto |
| ||
Features | Air Filter |
|
|
|
|
|
|
| Washable, | ||||
Compressor |
|
|
|
|
|
|
| DC Twin Rotary (Inverter) | |||||
Refrigerant / Amount charged at shipment |
|
| Ibs (g) |
| R410A / 2.87 (1,300) | ||||||||
Refrigerant Control |
|
|
|
|
|
| Electric Expansion Valve | ||||||
|
|
|
|
|
|
|
| ||||||
|
| Operation Sound |
| Indoor : Hi/Me/Lo/Qt* | 42 / 38 / 30 / 28 |
| 41 / 38 / 30 / 28 | ||||||
|
| (*Qt = Quiet mode) |
| Outdoor : Hi |
|
|
| 51 |
|
| 52 | ||
|
| Refrigerant Tubing Connections |
|
|
|
| Flare Type |
| |||||
|
| Max. allowable tubing length at shipment |
|
| ft (m) |
| 25 (7.5) |
| |||||
|
| Refrigerant |
|
| Narrow tube |
|
| inch (mm) |
| 1/4 (6.35) |
| ||
|
| Tube Diameter |
| Wide tube |
|
| inch (mm) |
| 1/2 (12.7) |
| |||
|
| Refrigerant Tube Kit / Accessories |
|
|
|
| Optional / Air Clean Filter | ||||||
Weight |
|
|
|
|
|
|
|
| Indoor Unit |
|
| Outdoor Unit | |
Unit Dimensions |
|
|
|
| inch |
| |||||||
Height ⋅ Width ⋅ | Depth |
|
| (mm) | (298 ⋅ 1,065 ⋅ 218) |
| (670 ⋅ 880 ⋅ 285) | ||||||
& |
|
|
|
| |||||||||
| Package Dimensions |
|
|
|
| inch |
| ||||||
Dimensions |
|
|
|
|
| ||||||||
Height ⋅ Width ⋅ Depth |
|
| (mm) | (289 ⋅ 1,140 ⋅ 379) |
| (740 ⋅ 1,012 ⋅ 380) | |||||||
Weight |
|
| Net |
|
| Ibs (kg) |
| 26.5 (12.0) |
|
| 97.0 (44.0) | ||
|
|
| Shipping |
|
| Ibs (kg) |
| 33.1 (15.0) |
|
| 105.8 (48.0) | ||
Shipping Volume |
|
|
|
| cu.ft (m3) |
| 4.23 (0.12) |
|
| 9.88 (0.28) |
|
| DATA SUBJECT TO CHANGE WITHOUT NOTICE. | |
Remarks: Rating conditions are: |
|
|
|
Cooling: Indoor air temperature | 80°F D.B. / 67°F W.B. | Heating: Indoor air temperature | 70°F D.B. |
Outdoor air temperature | 95°F D.B. / 75°F W.B. | Outdoor air temperature | 47°F D.B. / 43°F W.B. |
6