Sanyo CH1872, CH2472 service manual Cooling Capacity, KHS1872

Models: CH1872 CH2472

1 111
Download 111 pages 55.76 Kb
Page 23
Image 23
5-2. Cooling Capacity

5-2. Cooling Capacity

Indoor Unit

: KHS1872

 

 

 

 

 

 

 

 

 

 

 

Outdoor Unit

: CH1872

 

 

 

 

 

 

 

 

 

 

 

Power Supply : 230V Single Phase 60Hz

 

 

 

 

 

 

 

 

 

< Cooling Capacity >

 

 

 

 

 

 

 

 

 

 

RATING CAPACITY:

17,500 BTU/h

 

AIR FLOW RATE:

524 CFM

 

INDOOR

 

 

 

 

OUTDOOR

 

 

 

 

 

ENT. TEMP. oF (oC)

 

 

AMBIENT TEMP. oF (oC)

 

 

 

W.B.

 

D.B.

 

65

75

85

 

95

105

115

 

 

 

 

 

 

(18.3)

(23.9)

(29.4)

 

(35.0)

(40.6)

(46.1)

 

 

 

 

 

TC

17,710

17,180

16,600

 

16,040

15,320

10,530

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

72

(22.2)

SHC

13,110

12,910

12,610

 

12,300

12,000

9,760

 

59

 

76

(24.4)

SHC

14,840

14,640

14,340

 

14,030

13,720

10,530

 

(15.0)

 

80

(26.7)

SHC

16,670

16,370

16,060

 

15,860

15,320

10,530

 

 

 

84

(28.9)

SHC

17,710

17,180

16,600

 

16,040

15,320

10,530

 

 

 

88

(31.1)

SHC

17,710

17,180

16,600

 

16,040

15,320

10,530

 

 

 

 

 

TC

18,460

17,920

17,330

 

16,770

16,040

10,770

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

72

(22.2)

SHC

11,080

10,880

10,570

 

10,370

9,960

7,720

 

63

 

76

(24.4)

SHC

12,810

12,610

12,300

 

12,000

11,690

9,450

 

(17.2)

 

80

(26.7)

SHC

14,640

14,340

14,130

 

13,830

13,520

10,770

 

 

 

84

(28.9)

SHC

16,370

16,060

15,860

 

15,560

15,250

10,770

 

 

 

88

(31.1)

SHC

18,100

17,790

17,330

 

16,770

16,040

10,770

 

 

 

 

 

TC

19,190

18,650

18,060

 

#

17,500

16,750

10,980

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

72

(22.2)

SHC

9,050

8,740

8,540

 

8,330

8,030

5,790

 

67

 

76

(24.4)

SHC

10,780

10,470

10,270

 

10,060

9,760

7,520

 

(19.4)

 

80

(26.7)

SHC

12,500

12,300

12,100

 

11,790

11,490

9,250

 

 

 

84

(28.9)

SHC

14,230

14,030

13,830

 

13,520

13,220

10,980

 

 

 

88

(31.1)

SHC

15,960

15,760

15,450

 

15,250

14,950

10,980

 

 

 

 

 

TC

19,880

19,350

18,760

 

18,220

17,460

11,160

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

72

(22.2)

SHC

6,810

6,600

6,400

 

6,200

5,890

3,650

 

71

 

76

(24.4)

SHC

8,540

8,330

8,130

 

7,930

7,620

5,380

 

(21.7)

 

80

(26.7)

SHC

10,270

10,060

9,860

 

9,660

9,350

7,210

 

 

 

84

(28.9)

SHC

12,000

11,790

11,590

 

11,390

11,080

8,940

 

 

 

88

(31.1)

SHC

13,720

13,520

13,320

 

13,110

12,810

10,670

 

 

 

 

 

TC

20,470

19,940

19,350

 

18,830

18,070

11,270

 

75

 

 

 

 

 

 

 

 

 

 

 

 

 

76

(24.4)

SHC

6,300

6,200

5,990

 

5,790

5,490

3,350

 

(23.9)

 

80

(26.7)

SHC

8,130

7,930

7,720

 

7,620

7,320

5,180

 

 

 

84

(28.9)

SHC

9,860

9,660

9,450

 

9,350

9,050

6,910

 

 

 

88

(31.1)

SHC

11,590

11,390

11,180

 

10,980

10,780

8,640

 

 

 

 

 

TC : Total

Cooling

Capacity (BTU/h) SHC : Sensible Heat Capacity (BTU/h)

NOTE

1.Rating conditions (#) : Indoor Unit Entering Air Temp. 80 °F (26.7 °C) D.B. / 67 °F (19.4 °C) W.B.

:Outdoor Ambient Temp. 95 °F (35 °C) D.B.

2.Above data does not take Freeze Prevention Protection during cooling operation into account. For this reason, the value may vary from the actual cooling characteristics.

3.Above data represents the value when the operation frequency of a compressor is fixed.

23