Indoor Unit

: KHS2472

 

 

 

 

 

 

 

 

 

 

Outdoor Unit

: CH2472

 

 

 

 

 

 

 

 

 

 

Power Supply : 230V Single Phase 60Hz

 

 

 

 

 

 

 

 

 

< Cooling Capacity (Low Ambient) >

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATING CAPACITY:

24,200 BTU/h

 

AIR FLOW RATE:

 

600 CFM

 

 

INDOOR

 

 

 

 

OUTDOOR

 

 

 

 

 

ENT. TEMP. oF (oC)

 

 

 

 

AMBIENT TEMP. oF (oC)

 

 

 

 

W.B.

D.B.

 

 

0

5

15

25

 

35

45

55

 

 

 

 

 

 

(-17.8)

(-15.0)

(-9.4)

(-3.9)

 

(1.7)

(7.2)

(12.8)

 

 

 

 

TC

 

20,890

20,930

20,770

20,940

 

20,890

20,850

20,890

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

72 (22.2)

SHC

 

15,200

15,200

15,200

15,320

 

15,200

15,200

15,200

 

 

59

76 (24.4)

SHC

 

17,180

17,180

17,070

17,180

 

17,180

17,180

17,180

 

 

(15.0)

80 (26.7)

SHC

 

19,160

19,160

19,050

19,160

 

19,160

19,160

19,160

 

 

 

84 (28.9)

SHC

 

20,890

20,930

20,770

20,940

 

20,890

20,850

20,890

 

 

 

88 (31.1)

SHC

 

20,890

20,930

20,770

20,940

 

20,890

20,850

20,890

 

 

 

 

TC

 

20,710

20,780

20,760

21,120

 

21,130

21,160

21,310

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

72 (22.2)

SHC

 

12,400

12,400

12,400

12,640

 

12,640

12,640

12,750

 

 

63

76 (24.4)

SHC

 

14,380

14,380

14,380

14,500

 

14,500

14,500

14,620

 

 

(17.2)

80 (26.7)

SHC

 

16,370

16,370

16,370

16,480

 

16,600

16,600

16,600

 

 

 

84 (28.9)

SHC

 

18,230

18,350

18,230

18,470

 

18,470

18,470

18,580

 

 

 

88 (31.1)

SHC

 

20,210

20,210

20,210

20,330

 

20,330

20,450

20,450

 

 

 

 

TC

 

20,300

20,400

20,560

21,150

 

21,250

21,360

21,620

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

72 (22.2)

SHC

 

9,610

9,610

9,610

9,950

 

9,950

9,950

10,070

 

 

67

76 (24.4)

SHC

 

11,470

11,470

11,590

11,820

 

11,820

11,940

12,050

 

 

(19.4)

80 (26.7)

SHC

 

13,450

13,570

13,570

13,800

 

13,920

13,920

14,040

 

 

 

84 (28.9)

SHC

 

15,430

15,430

15,550

15,780

 

15,780

15,900

16,020

 

 

 

88 (31.1)

SHC

 

17,300

17,420

17,420

17,650

 

17,770

17,770

17,880

 

 

 

 

TC

 

19,590

19,740

20,120

21,010

 

21,200

21,410

21,820

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

72 (22.2)

SHC

 

6,570

6,570

6,810

7,040

 

7,160

7,270

7,390

 

 

71

76 (24.4)

SHC

 

8,440

8,560

8,670

9,020

 

9,020

9,140

9,370

 

 

(21.7)

80 (26.7)

SHC

 

10,540

10,540

10,650

11,000

 

11,120

11,120

11,350

 

 

 

84 (28.9)

SHC

 

12,400

12,520

12,640

12,990

 

12,990

13,100

13,220

 

 

 

88 (31.1)

SHC

 

14,380

14,380

14,500

14,850

 

14,970

14,970

15,200

 

 

 

 

TC

 

18,650

18,840

19,490

20,700

 

20,980

21,310

21,860

 

 

75

 

 

 

 

 

 

 

 

 

 

 

 

 

76 (24.4)

SHC

 

5,640

5,640

5,870

6,340

 

6,460

6,460

6,690

 

 

(23.9)

80 (26.7)

SHC

 

7,620

7,740

7,860

8,320

 

8,440

8,560

8,670

 

 

 

84 (28.9)

SHC

 

9,610

9,610

9,840

10,190

 

10,300

10,420

10,650

 

 

 

88 (31.1)

SHC

 

11,470

11,590

11,700

12,170

 

12,290

12,400

12,520

 

 

 

 

TC : Total Cooling Capacity (BTU/h)

SHC : Sensible Heat Capacity (BTU/h)

NOTE

1.Above data does not take Freeze Prevention Protection during cooling operation into account. For this reason, the value may vary from the actual cooling characteristics.

2.Above data represents the value when the operation frequency of a compressor is fixed.

26

Page 26
Image 26
Sanyo CH2472, CH1872 service manual 24,200 BTU/h