Maintenance and Care

Lamp Replacement

When the projection lamp of the projector reaches its end of life, the Lamp replacement icon appears on the screen and LAMP REPLACE indicator lights orange. Replace the lamp with a new one after it has cooled down. The timing when the LAMP REPLACE indicator lights up is depending on the mode that you specified for the Lamp control function.

LAMP REPLACE indicator

Lamp replacement icon

WARNING:

TURN OFF THE UV LAMP BEFORE

OPENING THE LAMP COVER.

LAMP REPLACE indicator

LAMP 1/2/3/4 REPLACE indicators

CAUTION

Allow the projector to cool for at least 20 minutes before you open the lamp cover. The temperature inside the projector becomes very hot.

CAUTION

CAUTION

-For continued safety, replace with a lamp assembly of the same type.

-Do not drop the lamp assembly or touch a glass bulb! The glass can shatter and may cause injury.

-When replacing the lamp, do it within 30 minutes after opening the lamp cover.

-Do not insert hand in the empty lamp compartment after the lamp is removed.

When replacing the lamp because it has stopped illuminating, there is a possibility that the lamp may be broken. If replacing a lamp of the projector which has been installed on the ceiling, you should always assume that the lamp is broken, and you should stand to the side of the lamp cover, not underneath it. Remove the lamp cover gently. Small pieces of glass may fall out when the lamp cover is opened. If pieces of glass get into your eyes or mouth, seek medical advice immediately.

Follow these steps to replace the lamp.

1

Check the LAMP 1/2/3/4 REPLACE indicators on top

of the projector. When any of the indicators blinks

 

rapidly, wait at least 20 minutes until it blinks slowly.

 

After that, go to the next step. When any of the

 

indicators blinks slowly, go to the next step.

2

Loosen the screw on the lamp cover. Open the lamp

 

cover. (See the right upper figure.)

3

Loosen the two screws that securing the lamp and

 

pull out the lamp by using the handle. (See the right

 

lower figure.)

4

Replace the lamp with a new one and tighten the

 

two screws. Make sure the lamp is set properly.

5

Close the lamp cover and tighten the screw.

LAMP COVER

SCREW

LAMP 3 LAMP 4

LAMP 2

SCREW HANDLE

SCREW

LAMP 1

76