ADJUSTING THE TABLE iNSERT

(Fig. ii)

[,A WARNING]

To avoid serious injury, the table

insert (2) must be level with the table, if the table insert is not flush

with the table, adjust the two bolts

(1)with a 4 mm he× wrench until it is parallel with the table.

NOTE: To raise the insert, turn the hex screws counterclockwise. To lower the insert, turn the hex screws clockwise.

Do not remove the insert, adjustments need to be made with the insert in

place to get the proper level.

Fig. II

REMOVING THE BLADE (Fig. S, T, U)

I,,A WARNING]

To avoid injury from an accidental start, make sure the switch is in the OFF position and the plug is disconnected from the power source outlet.

1.Remove the table insert by snapping out from the hole (8). (Fig. S)

2.Raise the blade to the maximum

height by turning the blade elevation handwheel clockwise.

3.Adjust the blade to the 90 ° vertical position by unlocking the blade

tilting lock knob, push in the blade elevation wheel and turn the bevel

tilting handwheel counterclockwise, and then lock into position.

4.Place the box-end wrench (7) on the arbor nut (2). (Fig. U)

5.Place the open-end wrench (6) on the flats of the saw arbor to keep the arbor from turning and loosen the arbor nut (2). (Fig. U)

6.Then remove the blade. Clean but do not remove the inner blade flange before reassembling the blade.