Sharp AR-M200 operation manual Misfeed in the transport area, Lower the fusing unit release lever

Models: AR-M200

1 111
Download 111 pages 31.37 Kb
Page 80
Image 80

TROUBLESHOOTING AND MAINTENANCE

2 Gently remove the misfed paper from under the fusing unit as shown in the illustration. If the paper cannot be removed, proceed to "C: Misfeed in the transport area".

Warning

The fusing unit is hot. Do not touch the fusing unit when removing misfed paper. Doing so may cause a burn or other injury.

Caution

Do not touch the surface of the drum (green portion) of the drum cartridge when removing the misfed paper. Doing so may cause smudges on copies.

Do not remove the misfed paper from above the fusing unit. Unfixed toner on the paper may stain the paper transport area, resulting in smudges on copies.

3 Raise the fusing unit release lever and then close the side cover by pressing the round projections near the side cover open button. The error indicator will go out and the ready indicator will light up.

C:Misfeed in the transport area

1Lower the fusing unit release lever.

See "B: Misfeed in the fusing area" (p.77).

2Open the front cover.

To open the front cover, see "TONER CARTRIDGE REPLACEMENT" (p.80).

3 Rotate the roller rotating knob in the direction of the arrow and gently remove the misfed paper from the exit area.

Roller rotating knob

78

Page 80
Image 80
Sharp AR-M200 operation manual Misfeed in the transport area, Lower the fusing unit release lever, Open the front cover