A and

TROUBLESHOOTING AND MAINTENANCE

6 Close the front cover and then the side cover by pressing the round projections near the side cover open button. The error indicator will go out and the ready indicator will light up.

Caution

When closing the covers, be sure to close the front cover securely and then close the side cover. If the covers are closed in the wrong order, the covers may be damaged.

Even after a new toner cartridge is installed, the start ( ) indicator Note may not light up, indicating copying cannot be restarted (toner is not

sufficiently fed). In this case, open and close the side cover. The copier will feed toner again approximately 2 minutes and then copying can be restarted.

SCAN HEAD LOCKING SWITCH

The scan head locking switch is under the original table. If the switch is locked ( ), the unit will not operate. Unlock the switch ( ) as shown below.

Grasp here and turn in the direction of the arrow.

A

LockUnlock

To lock the scan head locking switch, hold up the catch in illustration turn the center knob counter-clockwise 90 degrees until you hear a click.

82

Page 84
Image 84
Sharp AR-M200 operation manual Scan Head Locking Switch, LockUnlock