Sharp XG-P25X Wired Remote Control Terminal Specifications, Function and transmission codes

Models: XG-P25X

1 80
Download 80 pages 57.27 Kb
Page 74
Image 74
Wired Remote Control Terminal Specifications

Wired Remote Control Terminal Specifications Specifications of wired remote control input

Specifications of wired remote control input

ø3.5 mm minijack

External: 5 V (1 A)

Internal: GND

Function and transmission codes

CONTROL

SYSTEM CODE

 

DATA CODE

 

 

EXTERNAL

 

 

 

 

CODE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ITEM

C1

C2

C3

C4

C5

C6

C7

C8

C9

C10 C11 C12 C13 C14 C15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

1

0

1

1

0

0

1

1

0

1

0

1

0

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

1

0

1

1

0

0

1

1

0

1

0

0

1

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VOLUME 

1

0

1

1

0

0

0

1

0

1

0

0

0

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VOLUME 

1

0

1

1

0

1

0

1

0

1

0

0

0

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MUTE

1

0

1

1

0

1

1

1

0

1

0

0

0

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MENU

1

0

1

1

0

0

0

1

0

0

0

1

1

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LENS

1

0

1

1

0

1

1

0

1

0

0

0

1

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLACK SCREEN

1

0

1

1

0

1

0

0

1

0

1

1

0

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ENTER

1

0

1

1

0

1

1

1

0

1

0

1

0

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RESIZE

1

0

1

1

0

0

1

1

1

1

0

1

0

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UNDO

1

0

1

1

0

1

0

0

1

1

0

1

0

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Freeze

1

0

1

1

0

1

0

1

1

0

0

0

1

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Break Timer

1

0

1

1

0

0

0

1

0

1

1

0

1

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONTROL

SYSTEM CODE

 

DATA CODE

 

 

EXTERNAL

 

 

 

 

CODE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ITEM

C1

C2

C3

C4

C5

C6

C7

C8

C9

C10 C11 C12 C13 C14 C15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Enlarge

1

0

1

1

0

1

0

1

1

0

1

1

0

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Enlarge

1

0

1

1

0

1

0

1

1

0

1

0

1

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AUTO SYNC

1

0

1

1

0

0

1

0

1

1

1

1

1

1

0

1

0

1

1

0

0

0

1

1

1

0

0

1

1

0

ƒ

1

0

1

1

0

1

0

1

1

1

0

0

1

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ß

1

0

1

1

0

0

0

0

0

1

0

1

0

1

0

©

1

0

1

1

0

1

1

1

1

0

0

1

0

1

0

GAMMA

1

0

1

1

0

0

0

0

0

0

0

1

0

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT 1

1

0

1

1

0

1

0

1

0

1

1

0

0

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT 2

1

0

1

1

0

0

1

1

0

1

1

0

0

1

0

INPUT 3

1

0

1

1

0

1

0

1

0

1

1

0

1

1

0

INPUT 4

1

0

1

1

0

0

1

0

0

1

1

0

0

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT 5

1

0

1

1

0

1

1

0

0

1

1

0

0

1

0

To operate the mouse, left-click and right-click functions through the wired remote control input, connect the cable from the WIRED REMOTE control input terminal on the projector to the remote control. The codes for these functions are complex and are, therefore, not listed here.

Wired remote control function code

LSB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MSB

C1

 

 

System Code

 

 

C5

C6

 

 

 

 

Data Code

 

 

 

C13

C14

C15

1

 

0

 

1

1

 

0

*

*

 

*

*

*

*

 

*

*

1

0

System codes C1 to C5 are fixed at “10110”.

Codes C14 and C15 are reverse confirmation bits, with “10” indicating “Front” and “01” indicating “Rear”.

Sharp remote control signal format

Transmission format: 15-bit format

Appendix

E-71

 

 

 

D

 

 

D

 

D

 

 

D

 

D

 

D

 

 

D

 

D

 

D

 

 

D

 

D

 

D

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

67.5 ms

 

 

 

 

 

 

 

 

 

 

 

 

 

 

67.5 ms

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wave form of output signal: Output using Pulse Position Modulation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T1

 

 

 

 

T0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

26.4 s

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

“1”

 

 

 

“0”

“0”

 

“0”

 

 

 

 

 

 

 

 

 

 

 

 

“0”

 

“1”

 

 

 

“0”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• t 264 µs

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Pulse carrier frequency 455/12 kHz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• T0 1.05 ms

 

 

 

 

 

 

 

 

• Duty ratio 1:1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• T1 2.10 ms

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Transmission control code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15 bit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Example of Reverse D to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C1

C2

C3

C4

 

C5

C6

 

C7

 

C8

C9

C10

C11

C12

C13

C14

C15

 

 

D

 

C1

 

C2

C3

 

C4

 

C5

 

C6

 

C7

C8

 

C9

 

C10

C11

C12

C13

C14

C15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

0

1

 

1

0

 

 

1

 

0

0

 

0

 

0

 

0

0

0

1

0

 

 

 

 

 

System Address

 

 

 

 

 

 

 

Function Key Data Bit

 

 

 

Data

Mask

Data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Expansion

Deter-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

mination

 

 

D

 

C1

 

C2

C3

 

C4

 

C5

 

C6

 

C7

C8

 

C9

 

C10

C11

C12

C13

C14

C15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

0

1

 

1

0

 

 

0

 

1

1

 

1

 

1

 

1

1

1

0

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D to D Common Data Bit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reverse in D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

XG-P25X/CD (E)-h

71

02.3.19, 7:13 PM

Page 74
Image 74
Sharp XG-P25X operation manual Wired Remote Control Terminal Specifications, Specifications of wired remote control input