Appendix A Technical Specifications
Dimensions
SAMMS-MV
Handheld Communicator
Environments
Operating temperature range Storage temperature Relative humidity
Altitude
Vibration
Electrostatic discharge Electromagnetic interference Radio frequency interference
Control Power Specifications
Unit powered by
Power requirements
Control circuit inputs
Control circuit outputs
Maximum output loading allowed for continuous operation
Frequency
6.25inches W; 6.00 inches H; 2.125 inches D
3.15inches W; 5.7 inches H; 1.37 inches D
5to 95%
5g's at a frequency range of 10 to 60 Hz.
No hardware failures at 15 kV at any point in the front of the unit.
5kV repeated pulses, per
12.00VAC (+10%,
4VA
120 VAC or 125 VDC (+10%,
120 VAC (+10%,
1.0A for each output energized Maximum leakage current allowed: 5mA
50 Hz: +4%,
60 Hz: ± 5%
46