Appendix A Technical Specifications

Dimensions

SAMMS-MV

Handheld Communicator

Environments

Operating temperature range Storage temperature Relative humidity

Altitude

Vibration

Electrostatic discharge Electromagnetic interference Radio frequency interference

Control Power Specifications

Unit powered by

Power requirements

Control circuit inputs

Control circuit outputs

Maximum output loading allowed for continuous operation

Frequency

6.25inches W; 6.00 inches H; 2.125 inches D

3.15inches W; 5.7 inches H; 1.37 inches D

-25º C to +70º C. -40º C to +85º C.

5to 95% non-condensing. 6600 ft.

5g's at a frequency range of 10 to 60 Hz.

No hardware failures at 15 kV at any point in the front of the unit.

5kV repeated pulses, per UL-991 and ANSI C37.90A. Up to 95 MHz and 61.3 V/M field strength

12.00VAC (+10%, -15%) supply

4VA

120 VAC or 125 VDC (+10%, -15%)

120 VAC (+10%, -15%)

1.0A for each output energized Maximum leakage current allowed: 5mA

50 Hz: +4%, -5%

60 Hz: ± 5%

46

Page 48
Image 48
Siemens SAMMS-MV user manual Dimensions