INSTALLATION

100 Mbps Fast Ethernet Collision Domain

SMC 3 - 2 Rule for Class II Repeaters

Between any two PCs or other stations in the same 100BASE-T collision domain, there may be:

up to 3 link segments and

up to 2 Class II repeaters (hubs)

SMC 2 - 1 Rule for Class I and Class II Repeaters

Between any two PCs or other stations in the same 100BASE-T collision domain, there may be:

up to 2 link segments and

only 1 Class I or Class II repeater (hub)

Maximum 100BASE-T Network Diameter

Repeater Type

Twisted Pair

Twisted Pair/Fiber

and Number

100BASE-TX/T4

100BASE-T4/FX

100BASE-TX/FX

 

 

 

 

 

 

 

 

 

1 Class

I

200 m (656 ft.)

231 m (757.7 ft.)

 

260.8 m (855.4ft.)

 

 

 

 

 

 

 

 

 

1 Class

II

200 m (656 ft.)

304 m (997.1 ft.)

 

308.8 m (1012.9 ft.)

 

 

 

 

 

 

 

 

 

2 Class

II

205 m (672.4 ft.)

236.3 m (775.1 ft.)

 

216.2 m (709.1 ft.)

 

 

 

 

 

 

 

 

Maximum 100BASE-T Cable Distance

 

 

 

 

 

 

 

 

 

 

Cable Type

 

Connecting

 

Max. Distance

 

 

 

 

 

 

 

Twisted Pair

 

Any two devices

 

100 m (328 ft.)

 

 

 

 

 

 

 

 

Fiber

 

 

Switch to Switch, Server or PC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Half duplex

 

412 m (1,351.4 ft.)

 

 

 

 

 

 

 

 

 

 

 

Full duplex

 

2 km (1.24 mi.)

 

 

 

 

 

 

 

 

MII

 

 

Any two devices

 

0.5 m (1.6 ft.)

 

 

 

 

 

 

 

 

 