100 Mbps Fast Ethernet Collision Domain

SMC 3 - 2 Rule for Class II Repeaters
SMC 2 - 1 Rule for Class I and Class II Repeaters
Maximum 100BASE-T Network Diameter
Maximum 100BASE-T Cable Distance
INSTALLATION
3-10
Between any two PCs or other stations in the same 100BASE-T
collision domain, there may be:
up to 3 link segments and
up to 2 Class II repeaters (hubs)
Between any two PCs or other stations in the same 100BASE-T
collision domain, there may be:
up to 2 link segments and
only 1 Class I or Class II repeater (hub)
Repeater Type Twisted Pair Twisted Pair/Fiber
and Number 100BASE-TX/T4 100BASE-T4/FX 100BASE-TX/FX
1 Class I 200 m (656 ft.) 231 m (757.7 ft.) 260.8 m (855.4ft.)
1 Class II 200 m (656 ft.) 304 m (997.1 ft.) 308.8 m (1012.9 ft.)
2 Class II 205 m (672.4 ft.) 236.3 m (775.1 ft.) 216.2 m (709.1 ft.)
Cable Type Connecting Max. Distance
Twisted Pair Any two devices 100 m (328 ft.)
Fiber Switch to Switch, Server or PC
Half duplex 412 m (1,351.4 ft.)
Full duplex 2 km (1.24 mi.)