INSTALLATION
100 Mbps Fast Ethernet Collision Domain
SMC 3 - 2 Rule for Class II Repeaters
Between any two PCs or other stations in the same
•up to 3 link segments and
•up to 2 Class II repeaters (hubs)
SMC 2 - 1 Rule for Class I and Class II Repeaters
Between any two PCs or other stations in the same
•up to 2 link segments and
•only 1 Class I or Class II repeater (hub)
Maximum 100BASE-T Network Diameter
Repeater Type | Twisted Pair | Twisted Pair/Fiber | ||||||
and Number |
|
|
| |||||
|
|
|
|
|
|
|
|
|
1 Class | I | 200 m (656 ft.) | 231 m (757.7 ft.) |
| 260.8 m (855.4ft.) | |||
|
|
|
|
|
|
|
|
|
1 Class | II | 200 m (656 ft.) | 304 m (997.1 ft.) |
| 308.8 m (1012.9 ft.) | |||
|
|
|
|
|
|
|
|
|
2 Class | II | 205 m (672.4 ft.) | 236.3 m (775.1 ft.) |
| 216.2 m (709.1 ft.) | |||
|
|
|
|
|
|
|
| |
Maximum |
|
|
| |||||
|
|
|
|
|
|
| ||
Cable Type |
| Connecting |
| Max. Distance | ||||
|
|
|
|
|
|
| ||
Twisted Pair |
| Any two devices |
| 100 m (328 ft.) | ||||
|
|
|
|
|
|
|
| |
Fiber |
|
| Switch to Switch, Server or PC |
|
|
| ||
|
|
|
|
|
|
|
| |
|
|
|
| Half duplex |
| 412 m (1,351.4 ft.) | ||
|
|
|
|
|
|
| ||
|
|
|
| Full duplex |
| 2 km (1.24 mi.) | ||
|
|
|
|
|
|
|
| |
MII |
|
| Any two devices |
| 0.5 m (1.6 ft.) | |||
|
|
|
|
|
|
|
|
|