Table 3 - Write Register Summary

 

 

 

 

WRITE

 

 

 

 

ADDRESS

MSB

 

 

 

 

 

 

LSB

REGISTER

 

 

 

 

 

 

 

 

 

 

00

RI

0

0

0

EXCNAK RECON

NEW

TA

INTERRUPT

NEXTID

MASK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01

D7

D6

D5

D4

D3

D2

D1

D0

COMMAND

 

 

 

 

 

 

 

 

 

 

02

RDDATA

AUTO-

0

0

0

A10

A9

A8

ADDRESS

INC

PTR HIGH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

03

A7

A6

A5

A4

A3

A2

A1

A0

ADDRESS

PTR LOW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

04

D7

D6

D5

D4

D3

D2

D1

D0

DATA

 

 

 

 

 

 

 

 

 

 

05

0

0

0

0

0

0

0

0

RESERVED

 

 

 

 

 

 

 

 

 

 

06

RESET

CCHEN

TXEN

ET1

ET2

BACK-

SUB-

SUB-

CONFIG-

PLANE

AD1

AD0

URATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TID7

TID6

TID5

TID4

TID3

TID2

TID1

TID0

TENTID

 

 

 

 

 

 

 

 

 

NODEID

 

NID7

NID6

NID5

NID4

NID3

NID2

NID1

NID0

07

 

 

 

 

 

 

 

 

 

P1MODE

FOUR

ET3

RCV_

CKP3

CKP2

CKP1

SLOW

SETUP

 

 

NAKS

ALL

ARB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NEXT ID

 

0

0

0

0

0

0

0

0

 

 

 

 

 

 

 

 

 

 

21

Page 21
Image 21
SMSC COM20020 manual Write