English
4499
Calling up the list of fixed tare value memories for taring
The tare value from the fixed tare value memory can be activated when the scale is unladen
(before the weighing operation) or when the scale is laden (during the weighing operation).
• Aweight value appears in the display panel: e 0.000kg.
• First press the Print key and then simultaneously the Tare key.
• The last used fixed tare value memory appears in the display.
• Scroll to the required fixed tare value memory with the F key or Tare key or input the memory
location number and confirm with the Print key.
• Activate the fixed tare value by pressing the Print key.
• The display shows the gross value less the tare value (net).
• Further tare values from the memory are activated by repeating the procedure described
above.
Clearing an existing fixed value
• Press the Print key and the F key simultaneously; setting mode appears in the display.
• The arrow points to "Program Settings". Confirm with the Print key.
• The arrow points to "General". Confirm with the Print key.
• Scroll to "Fixed tare value" using the Tare key and accept with the Print key.
• The last selected fixed tare value memory is displayed.
• Scroll to the required fixed tare value memory with the F key or Tare key or input the memory
location number and confirm with the Print key.
• Clear the displayed fixed tare value memory with the C key.
• The gap in the consecutive number scheme is closed. The following fixed tare value memories are
given a number reduced by 1.
Error message when taring
"Error 06 Not possible to tare"
Possible causes:
Scale empty
Scale in overload or underload
Manual tare input with tare value above maximum load
Possible displays with the Info key
Display the tare memory by pressing the Info key, then press the Tare key. Pressing the Zeroing key
ends the display of the tare memory.