The 3. CAMERA RETURN
To confirm the status of a connection, proceed as follows.
1 Turn on the power of the unit and the camcorder.
2 Match the reference level of the unit and the camcorder.
Set the LEVEL switch on the right panel of the unit and the input level select switch on the camcorder to the same value.
When connecting with a +4 dBu reference output level:Set the LEVEL switch of the unit to +4 and the input level select switch of the camcorder to LINE.
When connecting with aSet the LEVEL switch of the unit to
3 Send a
The following table shows the reference position of each meter.
Output meter | Reference position |
|
|
VU | 0 |
|
|
PPM1 | 4 |
|
|
PPM2 | 0 |
|
|
PPM3 | 0 |
|
|
PPM4 | 0 |
|
|
dBFS | |
|
|
For detailed information on how to output the reference signal, see “To output the voice from the microphone or a
4 Adjust the REC level of the camcorder.
Adjust the level control of the camcorder so that the level meter of a camcorder points to 20.
The adjustment required for checking the status of a connection between the unit and the camcorder has been completed.
Now, perform a final check of the connection status using the 3. CAMERA RETURN
5 Display the 3. CAMERA RETURN
The CHECK window appears.
(continued)
35