Using the Unit to a Camcorder

6 Turn the ADJUST knob to the right so that CHECK blinks on the sub-menu, and then press the ADJUST knob.

The test signal is output and the unit starts checking the status of the connection.

When the unit and the camcorder are connected correctly, the following window appears.

When the L/R MASTER level control of the unit or the REC level of the camcorder is not correctly adjusted, the following window appears.

Center marker

Shows that the

Shows that the

level of the right

level of the left

signal is shifted

signal is shifted

away from the

away from the

correct position.

correct position.

When the marker is located on the left side of the center marker:

The level of the return signal from the camcorder is lower.

When the maker is located on the right side of the center marker:

The level of the return signal from the camcorder is higher.

In either case, the L/R MASTER level control of the unit or the REC level of the camcorder is not correctly adjusted.

Readjust the level so that the marker is located at the center, repeating steps 2 and 3, as necessary.

A message stating the result of the check also appears.

For detailed information on messages, see the following “Messages stating the results of check”, on page 37.

Note

This adjustment function of the return signal level is effective when a camcorder with a balanced output of 0 dBu is used.

7 Push the ADJUST menu.

The unit stops outputting the test signal and completes the check of the status of the connection.

To return to the setup menu

Turn the ADJUST knob to the left until the return mark blinks, and then press the ADJUST knob.