When you press the knob and release it instantly:

When you press the knob and release it instantly, the sound or signal continues to be output. When you press the knob and release it again, output ceases.

3 LCD (Liquid Crystal Display) What is displayed depends on the setting of the FUNCTION switch. For detailed information, see “4 FUNCTION switch.”

A heater is built into the LCD to be used in cold weather. This prevents the LCD from slowing down the display speed. The temperature is detected and the heater is automatically turned on or off.

Note

This heater is activated only with an external power supply. When the power is supplied from the batteries, the heater is not activated.

4 FUNCTION switch

LOCK: Set to this position to lock the controls and switches on the front panel to the settings at the time you set the switch to the LOCK position. Switches and controls locked are the Input level control, PAN control, LINK/M-S switch, MASTER control and MASTER LINK switch.

The PANEL LOCK sub menu of the SETUP menu allows you to decide which switches and controls are to be locked or unlocked.

LCD in the lock mode: Displayed in the display mode. You can select the item to be displayed by turning the ADJUST knob.

When you operate locked switches or controls: The following message is displayed to state that the switch or control is locked.

However, these switches and controls activate with the current settings when the FUNCTION switch is set to the SETUP or DISPLAY position.

When the power is turned off with the lock setting in place: Switches and controls are still locked when you turn on the power again.

SETUP: Set to this position to set parameters.

DISPLAY: Set to this position to display meters. The meter to be displayed is changed in the following sequence by turning the ADJUST switch: Full size level meter t Multi meter t Input level meter for channels 1 and 2 t Input level meter for channels 3 and 4 t Information.

SLATE: Set to this position to use the SLATE function. The SLATE switch becomes activated. The kind of the output signal depends on the setting of 2 SLATE switch.

11