Troubleshooting and Maintenance 6 Chapter

Troubleshooting

If an alarm message appears on the monitor screen, or if the unit appears to be malfunctioning, please check the following before contacting your Sony dealer.

Tape problems

Symptom

Cause

Remedy

 

 

 

Recording is not

The cassette’s REC/SAVE switch is set

Set the REC/SAVE switch to REC, or use another cassette.

possible.

to SAVE.

 

 

 

 

The unit’s tape

The REMOTE indicator in the display

Set the LOCAL/REMOTE switch to LOCAL to turn the

transport control

section is lit and the LOCAL ENABLE

REMOTE indicator off, or change the setting of the LOCAL

buttons (PLAY, F FWD,

menu item is set to STOP & EJECT or

ENABLE menu item (see page 67) to ALL ENABLE.

REW, etc.) do not

ALL DISABLE.

 

work.

 

 

No cassette is loaded.

Insert a cassette (see page 31).

 

 

 

 

The NO EDIT indicator

The audio recording mode selected on

• When your current purpose is editing, set the LOCAL/

on the front panel lights

this unit does not coincides with that of

REMOTE switch to LOCAL to turn the REMOTE indicator

up.

the loaded tape.

off and set the unit for the same audio recording mode as

 

 

with the tape using the REC MODE menu item (see page

 

 

73), then set the switch to REMOTE to light the REMOTE

 

 

indicator again.

 

 

• When your current purpose is recording, you can use the

 

 

tape currently loaded in the unit.

 

 

 

 

The recording format of the currently

Replace the tape with one recorded in the DVCAM format.

 

loaded tape is DV or DVCPRO.

 

 

 

 

 

The recording format selected on this

Select the DVCAM format.

 

unit is DV (SP).

 

 

 

 

 

 

 

Time data problems

 

 

 

 

 

Symptom

Cause

Remedy

 

 

 

Cannot freely set the

The TC MODE menu item is set to EXT

Change the setting of the TC MODE menu item (see page

initial time data value.

REGEN.

70) to INT PRESET.

 

 

 

 

CNT is selected as the time data type

Press the COUNTER SELECT button to make the TC or U-

 

to be displayed (the COUNTER time

BIT time data type indicator light up (the CNT value cannot

 

data type indicator is lit).

be set freely).

 

 

 

 

The REMOTE indicator in the display

Set the LOCAL/REMOTE switch to LOCAL to turn the

 

section is lit and the LOCAL ENABLE

REMOTE indicator off or change the setting of the LOCAL

 

menu item is set to STOP & EJECT or

ENABLE menu item (see page 67) to ALL ENABLE.

 

ALL DISABLE.

 

 

 

 

The tape is running,

The MENU button or TC PRESET

Press the button once again to exit the menu control mode,

but the time data is not

button in the menu control section has

time code preset mode, or digital hours meter display mode.

shown in the time

been pressed.

(In either of the menu control mode and time code preset

counter display.

 

mode, the time data is not shown in the time counter display.)

 

 

 

 

The U-BIT time data type indicator is lit.

Press the COUNTER SELECT button to make the

 

 

COUNTER or TC time data type indicator light up.

 

 

 

 

 

 

Input problem

 

 

 

 

 

Symptom

Cause

Remedy

 

 

 

It is not possible to

No SDTI signal is input to the unit, or

Connect an SDTI signal to the SDI/SDTI (QSDI) IN

record an SDTI (QSDI)

the SDTI format has not been selected.

connector, or set the DIGITAL OUTPUT menu item (see

signal.

 

page 75) to SDTI.

 

 

 

106 Troubleshooting