Displaying

Supplementary Status

Information

When you set the SUB STATUS menu item (see page 69) to other than OFF, you can view supplementary status information on the monitor screen below the operating mode display area.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T

C

R

 

0

0

:

0

4

.

4

7

.

0

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P

L

A

Y

 

 

 

 

 

L

O

C

K

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I

N

S

 

V

 

A

1

2

3

4

 

T

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Supplementary

 

status information

 

 

 

 

 

 

 

 

 

The following items of supplementary status information

 

 

are displayed depending on the setting of the SUB

 

 

STATUS menu item.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting of SUB

 

Items of supplementary

 

 

 

 

 

 

 

 

STATUS menu item

 

information displayed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EDIT PRESET

 

Editing mode settings made on the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

editing control unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TC MODE

 

Operating mode of the internal time

Chapter

 

REMAIN

 

Remaining capacity of the tape

 

 

 

 

 

 

 

 

 

code generator

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AUDIO MIXING

 

Setting for input audio mixing

Menu

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALL

 

All of the above items

Settings

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The following tables show the on-screen indications of

supplementary information and their meaning.

In each table, the indications given in brackets such as [ASM] are the indications displayed when the SUB STATUS menu item is set to ALL.

For the display format when ALL is selected, see the next section.

When the SUB STATUS menu item is set to EDIT

PRESET:

On-screen

Meaning

indication

 

 

 

ASM

Assemble editing mode

[ASM]

 

INS V A1234 TC INS: Insert editing mode

[V1234T]V A1234 TC: Channels or signals selected for insert editing

V:Video

A1234: Audio 1, 2, 3, 4

TC: Time code

When the SUB STATUS menu item is set to TC MODE:

On-screen

Meaning

indication

 

 

 

INT PRST FREE

The internal time code generator is

[IP F]

operating in FREE RUN mode.

 

 

INT PRST REC

The internal time code generator is

[IP R]

operating in REC RUN mode.

 

 

INT REGEN-T&U

The internal time code generator is in

[IRTU]

synchronization with the playback

 

time code (LTC) read from tape.

 

 

EXT LTC-T&U

The internal time code generator is in

[ELTU]

synchronization with the external time

 

code (LTC) input to the unit and is

 

generating the same time code value

 

and user bit value as those of the

 

external time code (regeneration).

 

 

EXT VITC-T&U

The internal time code generator is in

[EVTU]

synchronization with VITC present in

 

the external video signal input to the

 

unit and is generating the same time

 

code value and user bit value as

 

those of the external time code

 

(regeneration).

 

 

EXT QSDI-T&U

The internal time code generator is in

[EQTU]

synchronization with the external time

 

code input to the unit via the SDTI

 

(QSDI) interface and is generating the

 

same time code value and user bit

 

value as those of the external time

 

code (regeneration).

 

 

EXT QSDI. V-T&U

The internal time code generator is in

[EQTU]

synchronization with the external

 

VITC input to the unit via the SDTI

 

(QSDI) interface and is generating the

 

same time code value and user bit

 

value as those of the external time

 

code (regeneration).

 

 

EXT DVIN-T&U

The internal time code generator is in

[EDTU]

synchronization with the external time

 

code input to the unit via the i.LINK

 

(i.DV IN) interface and is generating

 

the same time code value and user bit

 

value as those of the external time

 

code (regeneration).

 

 

EXT DVIN. V-T&U

The internal time code generator is in

[EDTU]

synchronization with the external

 

VITC input to the unit via the i.LINK

 

(i.DV IN) interface and is generating

 

the same time code value and user bit

 

value as those of the external time

 

code (regeneration).

 

 

When the SUB STATUS menu item is set to REMAIN:

On-screen

Meaning

indication

 

 

 

REMAIN 184 min

Remaining capacity of the tape in

 

minutes.

 

When the remaining capacity has not

 

been calculated, “REMAIN --- min”

 

appears.

 

 

84 Displaying Supplementary Status Information