Overview 1 Chapter

When CH-3/4 mode is selected with the METER CH-1/

2 3/4 button:

Audio level meters

PHONES

MONITOR

 

connector

connector

 

 

 

CH-3 (channel 3) only.

Channel 3 only

Channel 3 only

Only the left meter lights.

(monaural)

 

 

 

 

CH-4 (channel 4) only.

Channel 4 only

Channel 4 only

Only the right meter

(monaural)

 

lights.

 

 

 

 

 

CH-3 and CH-4 (channels

Channels 3

Channels 3

3 and 4).

and 4 (stereo)

and 4 (mixed)

Both the left and right

 

 

meters light.

 

 

 

 

 

jMETER CH-1/2 3/4 button

Pressing this button toggles the audio level meter mode between CH-1/2 (channels 1 and 2) and CH-3/4 (channels 3 and 4).

The settings made with this button and the MONITOR SELECT button select the channels for level indications and audio output.

For more details, see “iMONITOR SELECT button.”

kCOUNTER SELECT button

Selects the type of time data to be shown in the time counter display. Each press of this button cycles through the following three indicator display options:

COUNTER (CNT: count value of the time counter)

TC (time code)

U-BIT (user bits)

Note

If the LOCAL/REMOTE switch is set to REMOTE, the COUNTER SELECT button does not operate while the tape is moving. In this case, make the time data selection via the external equipment connected to the REMOTE connector on the rear panel.

lCONTROL S connector (stereo minijack) Connect a SIRCS-compatible remote control unit such as the DSRM-10 to this connector.

AAudio input/output level control section

aREC/PB LEVEL control knobs

1

REC/PB

LEVEL

2

3

4

VAR

REC

PBPRESET

bVAR switch

aREC/PB LEVEL control knobs

These knobs used to control audio levels function differently depending on the setting of the VAR switch as follows.

VAR switch

Functions of control knobs

setting

 

 

 

PRESET

Control knobs are not effective.

 

The analog audio input/output levels are set to

 

the reference level set with the LEVEL

 

SELECT menu item (see page 74).

 

 

REC

Control the analog/digital audio input levels on

 

channels 1 to 4 during recording.

 

 

PB

Control the analog/digital audio output levels

 

on channels 1 to 4 during playback.

 

 

bVAR switch

Use to switch the way in which the REC/PB LEVEL control knobs function.

16 Location and Function of Parts