8-4

Items in the Extended Setup Menu

 

 

 

 

 

 

 

 

 

 

The extended setup menu contains the following

In the “Settings” column of the table, the factory

items.

 

 

 

 

 

 

 

 

 

default settings are indicated by an enclosing box.

 

 

Menu items in the range 100 to 199, relating to the control panels

 

 

 

 

 

 

 

 

 

 

 

Item number

 

Item name

 

Settings

 

101

 

SELECTION FOR

 

Select how the unit enters the search mode.

 

 

SEARCH DIAL ENABLE

 

 

 

 

: Turning the search dial switches to search mode.

 

DIAL

 

 

 

 

KEY: One of the JOG, SHUTTLE, and VAR buttons must be pressed to switch to

 

 

 

 

search mode.

 

102

 

MAXIMUM SPEED

 

Select the fast forward and rewind tape speed and also search mode speed

 

 

 

 

during tape playback.

 

 

 

 

 

: Perform fast forward, rewind, and search mode playback at the maximum

 

 

 

 

MAX

 

 

 

 

speeds.

 

 

 

 

 

MX/24: Perform fast forward and rewind at the maximum speeds, and search

 

 

 

 

mode playback at up to 24 times normal speed.

 

 

 

 

24: Perform fast forward and rewind at 24 times normal speed, and search

 

 

 

 

mode playback at up to 24 times normal speed.

 

 

 

 

Maximum fast forward and rewind speeds

 

 

 

 

• Analog cassette: 35 times (525-line mode) or 42 times (625-line mode) normal

 

 

 

 

speed.

 

 

 

 

 

• Betacam SX/MPEG IMX cassettes: 60 times normal speed (525-line mode) or

 

 

 

 

78 times (625-line mode)

 

 

 

 

Maximum search mode speeds

 

 

 

 

• Analog cassette: 35 times (525-line mode) or 42 times (625-line mode) normal

 

 

 

 

speed.

 

 

 

 

 

• Digital Betacam cassette: 50 times normal speed

 

 

 

 

 

 

 

103

 

AUDIO SELECTED LINE

 

Select the output signal to the MONITOR OUTPUT connectors.

 

 

OUT

 

MANU

: Output the signals selected by the audio signal selection buttons on the

 

 

 

 

lower control panel.

 

 

 

 

AUTO1: Output stereo, using the AFM channels (3 and 4) for playback from

 

 

 

 

metal tape, and the LNG channels (1 and 2) for playback from oxide tape.

 

 

 

 

AUTO2: Output the signals selected by the audio signal selection buttons on the

 

 

 

 

lower control panel, but during variable speed playback, if AFM is selected,

 

 

 

 

automatically switch to LNG.

104

 

AUDIO MUTING TIME

 

Select the length of time for which audio muting occurs when the unit switches to

 

 

 

 

playback either from stopped or from still playback in the search mode.

 

 

 

 

OFF

: Set the audio muting time to zero (i.e. no muting).

 

 

 

 

0.1S ... 1.0S: Set the audio muting time from 0.1 second to 1.0 second, in 0.1-

 

 

 

 

second increments.

105

 

REFERENCE SYSTEM

 

Select whether or not to display a warning when the video reference signal is not

 

 

ALARM

 

supplied.

 

 

 

 

 

OFF: No warning.

 

 

 

 

 

ON

: Flash the STOP button as a warning.

 

 

 

 

 

 

106

 

CAPSTAN LOCK

 

Select the capstan servo lock mode.

 

 

 

 

PANEL

: The capstan servo lock mode is determined by the function menu item

 

 

 

 

CAPSTN.

 

 

 

 

 

2F: The capstan servo locks every two fields regardless of the setting of the

 

 

 

 

function menu item CAPSTN.

 

 

 

 

4F: The capstan servo locks every four fields regardless of the setting of the

 

 

 

 

function menu item CAPSTN.

 

 

 

 

8F (For 625-line mode only): The capstan servo locks every eight fields

 

 

 

 

regardless of the setting of the function menu item CAPSTN.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Continued)

Chapter8 SetupMenus

Chapter 8 Setup Menus 8-7