Chapter8 SetupMenus
| Menu items in the range 400 to 499, relating to preroll | |||||
|
|
|
|
|
|
|
Item number | Item name | Settings | ||||
|
|
|
|
|
| |
401 | FUNCTION MODE | Select the state that the unit goes into after a | ||||
| AFTER CUEUP | STOP | : Stop (the “stop mode”) | |||
|
| STILL: Still playback (in search mode) | ||||
|
|
|
|
|
|
|
|
| Note |
| |||
|
| When controlling this unit from an editor with the standard constants set, select | ||||
|
| “STOP”. | ||||
|
|
|
|
|
|
|
402 | TIME REFERENCE FOR | When prerolling a tape with time code discontinuities, select whether or not to use | ||||
| PREROLL | CTL pulses to count time code from before a discontinuity. | ||||
|
| CTL | : Use CTL pulses to count time code. | |||
|
| TC: Do not use CTL pulses to count time code. | ||||
|
|
|
| |||
403 | AUTOMATIC PREROLL | Select whether or not the speed variation start point is automatically set by | ||||
| REFERENCE ENTRY | pressing the PREROLL button, when the speed variation start point is not set | ||||
|
| before starting preroll. | ||||
|
| DIS | : Speed variation start point is not set automatically. | |||
|
| ENA: Speed variation start point is set automatically. | ||||
405 | CUEUP BY CTL | Select the tape transport mode when cuing. This setting is valid only when the | ||||
|
| function menu item CTL/TC is set to CTL. | ||||
|
| CAP. | : During cuing up, the tape transport is in the “pinch ON” state (maximum | |||
|
| tape speed 10 times normal). | ||||
|
| REEL : During cuing up, the tape transport is in the “pinch OFF” state. As the | ||||
|
| tape approaches the cue up point and the tape speed drops, the tape transport | ||||
|
| switches to the “pinch ON” state.a) | ||||
|
| To give priority to editing accuracy, select “CAP”. | ||||
|
|
|
|
|
|
|
a)When controlled from an editor
Menu items in the range 500 to 599, relating to tape protection
Item number | Item name | Settings | ||||
|
|
|
|
|
|
|
501 | STILL TIMER | Select the time delay from the tape transport stopping (either the “stop mode” or | ||||
|
| the still playback mode in search mode) until the unit automatically switches to | ||||
|
| the tape protection mode, in order to protect the video heads and the tape. | ||||
|
| 0.5S ... 8M ... 30M: Set the value in the range 0.5 seconds to 30 minutes. | ||||
|
|
|
|
|
|
|
502 | TAPE PROTECTION | Select the operation of the protection mode to protect the video heads and tape | ||||
| MODE FROM SEARCH | when in the still playback mode in search mode (jog/shuttle). | ||||
|
| STEP | : Step forward at 1/30 normal speed every 2 seconds. | |||
|
| STDBY: Switch to “Standby OFF mode” (the unit not on standby). | ||||
|
| T.REL: Switch to tension release mode (the tape tension slackened). | ||||
|
|
|
|
|
|
|
503 | TAPE PROTECTION | Select the operation of the protection mode to protect the video heads and tape | ||||
| MODE FROM STOP | when stopped (the “stop mode”). | ||||
|
| STDBY | : Switch to “Standby OFF mode” (the unit not on standby). | |||
|
| T.REL: Switch to tension release mode (the tape tension slackened). | ||||
|
|
|
|
|
|
|
504 | DRUM ROTATION IN | Select whether the drum rotates in “Standby OFF mode”. | ||||
| STANDBY OFF | OFF | : Drum does not rotate. | |||
|
| ON: Drum rotates. | ||||
|
|
|
|
| ||
505 | STILL TENSION | Select the tape tension state in the still playback mode. | ||||
|
| NORM | : Normal tape tension is maintained during still playback mode, ready for | |||
|
| playback. | ||||
|
| LOOSE: Reduce the tape tension further from the NORM setting. (Select | ||||
|
| “LOOSE” when the unit is on standby for a long period of still playback, for | ||||
|
| example, in a library management system (LMS).) | ||||
|
|
|
| |||
|
| Note |
|
| ||
|
| When LOOSE is selected, playback cannot be guaranteed. | ||||
|
|
|
|
|
|
|