Menu items in the range 900 to 999, relating to digital processing

Item number

Item name

Settings

 

 

 

 

 

 

 

 

 

903a)

FREEZE MODE

Select the freeze mode and freeze timing.

 

 

FIELD

: Freeze a video field. Field may be odd or even, according to the timing.

 

 

FLD1:

Freeze an odd field.

 

 

FLD2: Freeze an even field.

 

 

FRM12: Freeze a frame consisting of an odd field and following even field.

 

 

FRM21: Freeze a frame consisting of an even field and following odd field.

 

 

Odd and even fields are distinguished by the reference video signal.

 

 

Changing the menu setting during a freeze does not affect the freeze image.

 

 

The setting is reflected the next time a freeze is carried out.

 

 

You can freeze an image using the DELETE button and TRIM + button.

 

 

For details, see menu item 904.

 

 

 

 

 

 

 

 

 

904a)

FREEZE CONTROL

Determine how the buttons used to freeze an image function.

 

FROM KEY PANEL

 

 

 

 

 

: Holding the DELETE button and pressing the TRIM + button carries out

 

MOMNT

 

 

a freeze. The freeze ends when the buttons are released.

 

 

LATCH: Holding the DELETE button and pressing the TRIM + button carries out

 

 

a freeze. The freeze continues even after the buttons are released.

 

 

• To update the freeze image

 

 

Hold the DELETE button and press the TRIM + button again.

 

 

• To end the freeze

 

 

Hold the DELETE button and press the TRIM – button.

905a)

AUTO FREEZE

Set the auto freeze function operation (conditions for ending a freeze, etc.).

 

CONTROL

In normal playback, if there is a sudden worsening of the channel condition (entry

 

 

into unrecorded area), this function freezes the image.

 

 

 

 

 

: Disable the auto freeze function.

 

 

DIS

 

 

 

MODE1: End the freeze when signals which can be played back normally are

 

 

restored.

 

 

MODE2: End freeze automatically on playback after stopping.

 

 

• The automatic freeze mode is determined by item 903.

 

 

• The freeze is ended immediately, regardless of the above conditions, when this

 

 

unit is switched to cue up or eject mode.

 

 

 

 

 

 

 

 

 

906a)

STOP FREEZE

Select whether or not the STOP FREEZE function should operate.

 

CONTROL

 

 

 

: Does not operate.

 

DIS

 

 

 

ENA: Operates.

 

 

 

 

 

915

SDTI-CP OUTPUT

Select whether or not to add an FEC (Forward Error Correction) signal for

 

FORWARD ERROR

protection against SDTI-CP signal transfer errors.

 

CORRECTION

ON

: Add an FEC signal.

 

 

OFF: Do not add an FEC signal.

 

 

 

 

 

 

Note

 

 

 

Although the FEC specifications are provided in the SDTI-CP (SMPTE 326M)

 

 

standards, FEC is not supported in some devices.

 

 

 

 

 

 

 

 

 

a) Not supported in this version of the unit