Speco Technologies 8TH, 4TH, 16TH Event Full Screen, Event Duration, Per Channel Config, Alert IP

Models: 16TH 4TH 8TH

1 175
Download 175 pages 52.16 Kb
Page 111
Image 111
5.6.5.3Alert IP

User’s Manual

5.6.5.3Alert IP

The Alert IP must match the IP address of the computer.

5.6.5.4Alert Port

The ports for both DVR and the CMS Alert must be the same.

5.6.5.5Alert Interval

To define the time interval (1 to 255 seconds) between each alive message.

5.6.6Event Full Screen

This function allows the unit to display the alarm channel in full screen size when an alarm is triggered.

Select <None> to enable this function; select <Main> to display the alarm channel on Main Monitor when an alarm is triggered; select <Call> to display the alarm channel on Call Monitor; and select <Both> to display the alarm channel on both Main Monitor and Call Monitor.

5.6.7Event Duration

This item determines the duration of the buzzer and Alarm Out relay function after an alarm is triggered. The available event duration range is from 5 second to 999 seconds.

5.6.8Per Channel Config

This menu is used to set the Video Loss Detect, Motion Detect and Alarm In / Out function for each channel. The menu is displayed as below.

Per Channel Config

 

Channel Select

CH01

Video Loss Detect

OFF

Motion Detect

OFF

Detection Config

OFF

Alarm In

Alarm Out

None

Digital Deterrent-Day

OFF

Digital Deterrent-Night

OFF

Digital Deterrent-Weekend

OFF

110

DVR-4TH/8TH/16TH Series

 

SPECO TECHNOLOGIES 07/10

Page 111
Image 111
Speco Technologies 8TH, 4TH Event Full Screen, Event Duration, Per Channel Config, Alert IP, Alert Port, Alert Interval