Off-Board Relays

D9412GV2/D7412GV2 Operation and Installation Guide 10.0

Off-Board Relays

 

 

Figure 21: D8129 Connections to the D7412GV2

amming

CONNECTIONS

POWER +

32

DATA BUS A

31

DATA BUS B

30

COMMON

29

 

 

ZONEX OUT 1

28

ZONEX IN 1

27

 

 

NOT USED

26

NOT USED

25

EX POWER +

24

X COMMON

23

Figure 21: D8129 Connections to the D7412GV2Manual backgroundManual background D5200/D5360

Manual background PROG CONN

2

3Manual background

3

GND

1

AUX

 

DATA

 

1

2

3

4

5

6

7 8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 - D8129 OctoRelays for relay numbers 1 to 64.

2 -

Power limited

Connect OctoRelays in parallel.

3 -

Supervised, power limited

10.1.1 Configuring the D8129 OctoRelay

Five switches on the OctoRelay determine the relay numbers for the eight relay outputs (Error! Reference source not found.).

Table 18: D8129 OctoRelay Switch Settings

 

 

 

 

Panel Relay

D8129 OctoRelay

On Panel, Connect

Number

Switch Setting

D8129 to:

1 to 8

Off-On-On-On-On

Zonex 1 Terminal 28

9 to 16

On-Off-On-On-On

Zonex 1 Terminal 28

17 to 24

Off-Off-On-On-On

Zonex 1 Terminal 28

25 to 32

On-On-Off-On-On

Zonex 1 Terminal 28

 

 

 

 

33 to 40

Off-On-Off-On-On

Zonex 1 Terminal 28

41 to 48

On-Off-Off-On-On

Zonex 1 Terminal 28

49 to 56

Off-Off-Off-On-On

Zonex 1 Terminal 28

57 to 64

On-On-On-Off-On

Zonex 1 Terminal 28

D7412G Maximum

 

65 to 72

 

Off-On-On-On-On

Zonex 2 Terminal 26

73 to 80

 

On-Off-On-On-On

Zonex 2 Terminal 26

81 to 88

 

Off-Off-On-On-On

Zonex 2 Terminal 26

 

 

 

 

89 to 96

 

On-On-Off-On-On

Zonex 2 Terminal 26

97 to 104

 

Off-On-Off-On-On

Zonex 2 Terminal 26

105 to 112

 

On-Off-Off-On-On

Zonex 2 Terminal 26

113 to 120

 

Off-Off-Off-On-On

Zonex 2 Terminal 26

121 to 128

 

On-On-On-Off-On

Zonex 2 Terminal 26

10.1.2

Relay Outputs

 

Relay outputs can activate when you are

 

setting the OctoRelay switches or

 

programming the control panel.

 

Disconnect equipment connected to relay

 

outputs when you perform these functions.

Each OctoRelay output provides a Form C dry contact rated for 1.0 A at 12 VDC. Normally-open, common, and normally-closed terminals are available for each relay output. When an individual output is activated, there is continuity between the normally-open and common terminals. When the output is not activated, there is continuity between the normally-closed and common terminals.

10.1.3 Installation

Set the switches on the OctoRelay before installing it in the enclosure. Refer to Section 10.1.1 Configuring the D8129 OctoRelay on this page.

Install the OctoRelay in the enclosure with the control panel (Figure 2 on page 9) or in an adjacent enclosure that is no more than 1.5 m (5 ft.) from the control panel. Use 1.5 mm (16 AWG) to 0.8 mm (22 AWG) wire.