D9412GV2/D7412GV2 Operation and Installation Guide 5.0 | Power Supply | |||
5.0 | Power Supply | 5. Secure the transformer to the outlet with the screw | ||
provided. | ||||
D8004 Transformer Enclosure Required for Fire | ||||
5.1 | Primary Power Terminals 1 and 2 | |||
Systems: Use the D8004 Transformer Enclosure for | ||||
5.1.1 Primary (AC) Power Circuit | the D1640 Transformer in fire and combined fire and | |||
The primary source is a 16.5 VAC, 40 VA, internally- | burglary applications. | |||
Check with the Authority Having Jurisdiction (AHJ) | ||||
fused transformer (Bosch Security Systems Model | ||||
D1640). The control panel draws 200 mA when idle | about mounting transformers on specific circuits. | |||
and 500 mA when in an alarm state. The total available | 5.2 | Secondary Power Terminals | ||
auxiliary current is 1.4 A. | 5.2.1 | Secondary (DC) Power | ||
Transient suppressors and spark gaps protect the circuit | ||||
A 12 V, 7 Ah (up to 14 Ah) sealed | ||||
from power surges. This protection relies on the | ||||
rechargeable battery (D126) supplies secondary power | ||||
ground connection at Terminal 10. Ensure that you | ||||
for auxiliary and alarm outputs, and powers the system | ||||
connect Terminal 10 to a proper ground. Refer to | ||||
during interruptions in primary (AC) power. | ||||
Section 4.5 Connecting Earth Ground on page 16. | ||||
|
| |||
AC Power Failure |
| Warning - Use Lead Acid Batteries Only: | ||
The system indicates an AC power failure when |
| The charging circuit is calibrated for lead- | ||
| acid batteries. Do not use | |||
Terminals 1 and 2 do not have power. The AC Fail |
| |||
| batteries. | |||
Time program item sets the number of minutes or |
| |||
Extra Batteries Increase | ||||
seconds without AC power before the control panel | ||||
acknowledges the failure and the number of minutes or | battery | |||
seconds after the power returns before the control | battery in parallel to the first battery to form a 12 V, 14 | |||
panel acknowledges restored power. Refer to the | Ah battery. Use a D122 Dual Battery Harness to ensure | |||
D9412GV2/D7412GV2 Program Entry Guide | proper and safe connection. | |||
(P/N: F01U003636) for additional information about |
| Caution: When connecting two D1218 | ||
AC Fail Time. |
| |||
| Batteries to the control panel, both must have | |||
5.1.2 | Installing the Transformer |
| ||
| the same capacity (use two 17.2 Ah batteries | |||
|
|
| ||
| Do not short the terminals of the |
| or two 18 Ah batteries). | |
| transformer: Shorting the terminals opens | D1218 Battery | ||
| the internal fuse, causing permanent failure. | The D1218 is a 12 V, 17.2 or 18 Ah battery for use in | ||
| Connect the transformer to Terminals 1 and | |||
| applications requiring extended battery standby time. | |||
| 2 of the control panel before plugging it into | |||
| Up to two D1218 batteries can be connected when | |||
| the power source. | |||
| used with a D122 Dual Battery Harness. | |||
|
|
1.Use 1.22 mm (18 AWG) wire (minimum) to connect the transformer to the control panel.
The wire length should be as short as possible. The maximum length is 15 m (50 ft.). Connect the battery and plug in the transformer.
2.Route telephone and sensor loop wiring away from any AC conductors, including the transformer wire.
AC wiring can induce noise and low level voltage into adjacent wiring. Route data wiring away from AC and telephone wiring.
Always connect the battery first and then plug in the transformer.
3.Connect the battery. Refer to Section 5.2.2 Installing the Battery on page 21.
4.Plug the transformer into an unswitched, 120 VAC, 60 Hz power outlet only.
20 | Bosch Security Systems, Inc. 5/05 F01U003641B |