D9412GV2/D7412GV2 Operation and Installation Guide Appendix A: System Wiring Diagrams, Issue A

Figure 35: D9412GV2, Input Points and Peripheral Devices

+-

D130

PHONE LINE

SEIZED

1CLASS 2 TRANSFORMER

16.5VAC 40 VA 60 Hz Model D1640

Internally Fused - Do Not short

2Requires Unswitched Outlet

Do Not Share With Other Equipment

3+ AUX POWER

4BATTERY NEGATIVE ONLY

Maximum Charging

Current 1.4 Amps.

5BATTERY POSITIVE ONLY

6

RELAY A

PROGRAMMABLE

ALARM OUTPUTS

 

 

Terminals

7

RELAY B

7 & 8

Requires Optional

 

 

 

 

Model D136 Relay

8In ALT ALARM

RELAY C

&SW AUX

9COMMON

10 EARTH GROUND

GROUND FAULT DETECT

Enabled

Disabled

 

PHONE

ON when

RED

communicating

 

LED

OFF when idle

 

PHONE LINE SEIZED

TIP

TELCO CORD RING

 

MODEL D161

D9412GV2

 

 

VOLTAGE RANGES

 

 

Open

3.7 - 5.0 VDC

 

 

Normal

2.0 - 3.0 VDC

 

 

Short

0.0 - 1.3 VDC

Point 1 Point 2

Point 3 Point 4

Point 5 Point 6

Point 7 Point 8

11

12

13

14

15

16

17

18

19

20

21

22

Point 8

D5200/D5360

S3 Option

PROG CONN

Closed = 1KEOL Manual backgroundManual background

Normal Operation

Open =AB-12 UL

Bell Box 220 K

GRN

TIP

RING

TELCO

P105F

D125B

Sw. Aux Pwr

1

 

Zone B

2

D129

Zone A

3

 

Pnl Common

4

 

Pnl Common

5

 

Loop B-

6

 

Loop A-

7

 

Loop B+

8

 

Loop A+

9

 

Earth Ground

10

 

P105BL

Loop B+

1

Loop B-

2

Loop B-

3

Loop B+

4

Zone B

5

Aux Power

6

Earth Ground

7

Common

8

Zone A

9

Loop A+

10

Loop A-

11

Loop A-

12

Loop A+

13

1 - (Optional): For 24 V applications use a UL Listed 24 VDC power supply with a D130 Relay Module. Refer to the D130 Installation Instructions

(P/N: 74-06262-00) for correct wiring requirements.

2 - To UL Listed two-wire smoke detectors. Refer to the 9000/G/GV2 Series Technical Service Note: UL Smoke Detector Compatibility (P/N: 33284) for a listing of compatible two-wire smoke detectors.

3 - P105 1 kEOLR (P/N: 14-03130-004): Suitable for non-powered initiating and supervisory devices such as pull stations, heat sensors, and valve tampers.

4- P105BL1 1kEOLR (P/N: 14-0130-004): For typical burglar alarm applications.

5 - D129 provides optional Waterflow Retard feature. Not suitable for two-wire smoke detectors. (Note: Use Zero Retard except for waterflow devices.)

All external connections except Terminal 5 (battery positive) are power limited.

Bosch Security Systems, Inc. 5/05 F01U003641B